Warning – Napoleon Fireplaces Bayfield - GDS25 Manuel d'utilisation

Page 35

Advertising
background image

This appliance comes equipped with our “Night Light”.
If in the event the lamp or lens needs to be replaced, follow these instructions.
Disconnect the two wire leads at the wire nut. Remove the four screws
securing the accent light assembly from the relief door. Disassemble the
light and the lamp now can be accessed
Note: Do not handle the lamp (bulb) with bare fi ngers, protect with
a clean dry cloth.
The lamp will pull straight out of the socket. Replace with Wolf Steel
parts only, as lamp and lens are special “high temperature” products.
When re-installing, ensure integrity of gasket seal.

THE FIREBOX MUST BE SEALED.

When re-assembling the light assembly, care must be taken
with all gaskets.
“Light Leakage” from above the cast doors may
be noticed. The holes in the lamp housing are
necessary for ventilation and must not be covered.

10.2 NIGHT LIGHT REPLACEMENT

GASKET

GLASS LENS

GASKET

SHEILD

RAIL

RAIL

WIRE NUT

COVER PLATE

RELIEF

DOOR

10.3 PILOT INJECTOR AND ORIFICE REPLACEMENT

ORIFICE

LOCATION

BURNER

ASSEMBLY

This must be carried out by an AUTHORIZED REPRESENTATIVE OF WOLF STEEL
LTD. or a QUALIFIED GAS INSTALLER in accordance with local codes or in the
absence of local codes with the requirements of the provincial / state authorities having
jurisdiction and in accordance with the requirements of the CAN1-B149 Installation Code
in Canada and the ANSI Z223.1 National Fuel Gas Code in the United States.

A.

Turn off the electrical and gas supply to the appliance.

B.

Remove the cast front, glass viewing door and log set.

C.

Remove the 2 securing screws. Slide the burner assembly to the right and lift
out.

D.

Using a deep socket wrench, remove the main burner orifi ce. A back-up wrench
must be used on themanifold, located below the housing to ensure that the
aluminum tubing does not twist or kink. Replace the correct burner orifi ce using
pipe thread compound.

E.

Loosen nut and replace with appropriate injector

F.

Reinstall the burner ensuring that the Venturi tube fi ts over the orifi ce.

G.

Turn on the gas supply and check for gas leaks by brushing on a soap and water solution.
Do not use open fl ame.

H.

Replace the log set. Then light the pilot and main burner to ensure that the gas lines have
been purged.

I.

Replace the glass viewing door and cast front. Turn on the electrical supply to the appliance.

!

WARNING

ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT

WITH THE GLASS DOOR OPEN OR REMOVED.

37.1A

Access the blower, if equipped and clean using a soft brush and vacuum.

Re-assemble the various components in reverse order.

Inspect the relief system. The appliance relief through the main glass door or through the fl aps on the
fi rebox top. Ensure they open freely, and close sealed.

W415-0547 / J / 07.16.13

35

EN

Advertising