Il i – Napoleon Fireplaces Bayfield - GDS25 Manuel d'utilisation

Page 51

Advertising
background image

FR

W415-0547 / G / 08.01.13

51

2.4 INFORMATION SUR LA PLAQUE D’HOMOLOGATION

A

4"

B

2"

C

2"

W385-0330 / E

NOT FOR USE WITH SOLID FUEL

GDS/CDVS25

CERTIFIED UNDER / HOMOLOGUE SELON LES NORMES: CSA 2.33-2009, ANSI Z21.88-2009 VENTED GAS FIREPLACE HEATER / FOYER DE CHAUFFAGE AU GAZ AVEC EVACUATION.

MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL:

VENT TOP

2" TO CEILING FROM

VENT BOTTOM

1" STOVE TOP 48”

VENT SIDES

1"

WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE. ONTARIO L4M 0G8 CANADA

UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE
UTILSE AVEC CET APPAREIL

EVENT SUPERIEUR 2" ENTRE LE DESSUS

DU FOYER

EVENT INFERIEUR 1" ET LE PLAFOND 48”
COTES DE L'EVENT 1"

A

4"

B

2"

C

2"

DEGAGEMENTS MINIMAUX DES MATERIAUX
COMBUSTIBLES:

SERIAL NUMBER / NO. DESERIE

APPROVED FOR BEDROOM, BATHROOM & BEDSITTING ROOM INSTALLATION.
SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH
THE CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE
HOMES, IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME
CONSTRUCTION AND SAFETY STANDARD, TITLE 24 CFR, PART 3280. WHEN
THIS US STANDARD IS NOT APPLICABLE USE THE STANDARD FOR FIRE
SAFETY CRITERIA FOR MANUFACTURED HOME INSTALLATIONS, SITES AND
COMMUNITIES, ANSI / NFPA 501A.

HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER, UNE SALLE DE
BAIN ET UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI

SON INSTALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA
Z240MH SERIE DE MAISONS MOBILES EQUIPEES AU GAZ, EN VIGUEUR AU
CANADA OU AUX ETATS-UNIS DE LA NORME DE SECURITE ET DE
CONSTRUCTION DE MAISONS MANUFACTUREES, TITRE 24 CFR, SECTION 3280.
DANS LE CAS OU CETTE NORME D'ETATS-UNIS NE PEUT ETRE APPLIQUEE, SE
REFERER A LA NORME RELATIVE AU CRITERE DE MESURES DE SECURITE
CONTRE L'INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS

MANUFACTURES, LES SITES ET LES COMMUNAUTES, ANSI/NFPA 501A.

MANIFOLD PRESSURE: 3.5” W.C. (NG)
PRESSION AU COLLECTEUR: 3.5" D'UNE
COLONNE D'EAU(GN)
MIN SUPPLY PRESSURE: 4.5" W.C.(NG)
PRESSION D'ALIMENTATION MIN: 4.5"
D'UNE COLONNE D'EAU (GN)
MAX. SUPPLY PRESSURE: 7" W.C. (NG)
PRESSION D'ALIMENTATION MAX: 7"
D'UNE COLONNE D'EAU (GN)
AFUE: 64%

MANIFOLD PRESSURE: 10” W.C. (LP)

PRESSION AU COLLECTEUR: 10" D'UNE

COLONNE D'EAU(P)

MIN SUPPLY PRESSURE: 11" W.C.(LP)

PRESSION D'ALIMENTATION MIN: 11"

D'UNE COLONNE D'EAU (P)

MAX. SUPPLY PRESSURE: 13" W.C. (LP)

PRESSION D'ALIMENTATION MAX: 13"

D'UNE COLONNE D'EAU (P)

AFUE: 64%

GDS25N

MODEL

GDS25P

0-2000ft

2000-4500ft

ALTITUDE / ELEVATION 0-2000ft

2000-4500ft

24,500 BTU/h

22,000 BTU/h

INPUT / ALIMENTATION

23,000 BTU/h

20,000 BTU/h

19,000 BTU/h

16,000 BTU/h

REDUCED INPUT /

16,000 BTU/h

14,000 BTU/h

ALIMENTATION REDUITE

9700539 (WSL)

4001657 (NGZ)

4001658

(NAC)

4001659

(WUSA)

FOR USE WITH GLASS DOORS CERTIFIED
WITH THIS UNIT ONLY.
WARNING: DO NOT ADD ANY MATERIAL TO
THE APPLIANCE, WHICH WILL COME IN
CONTACT WITH THE FLAMES, OTHER THAN
THAT SUPPLIED BY THE MANUFACTURER
WITH THE APPLIANCE.
ELECTRICAL RATING: 115V 1.5AMP 60HZ
THE APPLIANCE MUST BE VENTED USING
THE APPROPRIATE WOLF STEEL VENT
KITS. SEE OWNERS INSTALLATION MANUAL
FOR VENTING SPECIFICS. MINIMUM AND
MAXIMUM VERTICAL VENT LENGTHS ARE 3
FEET AND 40 FEET RESPECTIVELY.

MINIMUM AND MAXIMUM HORIZONTAL
VENT LENGTHS ARE 10 INCHES AND 20
FEET RESPECTIVELY. PROPER REINSTAL-
LATION AND RESEALING IS NECESSARY
AFTER SERVICING THE VENT-AIR INTAKE
SYSTEM.

UTILISER AVEC LES PORTES VITREES
HOMOLOGUEES SEULEMENT AVEC CETTE
UNITE.
AVERTISSEMENT: N'AJOUTEZ PAS A CET
APPAREIL AUCUN MATERIAU DEVANT
ENTRER EN CONTACT AVEC LES FLAMMES
AUTRE QUE CELUI QUI EST FOURNI AVEC
CET APPAREIL PAR LE FABRICANT.
CLASS.: 115V 1.5AMP 60HZ L'APPAREIL
DOIT EVACUER SES GAZ EN UTILISANT
L'ENSEMBLE D'EVACUATION PROPRE A
WOLF STEEL. REFERER AU MANUEL
D'INSTALLATION DE PROPRIETAIRE POUR
L'EVACUATION PRECISE. LES LONGUEURS
VERTICALES MINIMALES ET MAXIMALES
SONT3 PIEDS ET 40 PIEDS
RESPECTIVEMENT.

LES LONGUEURS HORIZONTALES MINIMALES ET
MAXIMALES SONT 10 POUCES ET 20 PIEDS
RESPECTIVEMENT.
IL EST IMPORTANT DE BIEN REINSTALLER ET
RESCELLER L'EVENT APRES AVOIR ASSURE LE
MAINTIEN DU SYSTEME DE PRISE D'AIR.

INSTALLATEUR :

Il est de votre responsabilité de cocher, sur la plaque d’homologation, les cases

correspondant au modèle, au type d’évacuation et au type de gaz de l’appareil.

Pour l’emplacement de la plaque d’homologation, voir la section « VUE D’ENSEMBLE DE L’INSTALLATION ».

Cette illustration est fournie à titre indicatif seulement. Pour les renseignements exacts, consultez la plaque
d’homologation fi xée sur l’appareil.

NOTE: Le plaque d’homologation doit rester avec l’appareil à tout le temps. Il ne doit pas être enlevé.

ÉCHANTILL

ON

ÉCHANTILL

ON

ÉCHANTILL

ON

ÉCHANTILL

ON

HHHHHHHHHA

HA

HA

HA

HA

HHHA

H

"

2
2"

ER DE CHAUFFAG

NCE TO COMBUST

NT TOP

VENT BOTTOM
VENT SIDES

RRIE. ONTARIO L4

N

ATION DANS UNE C

PRIE POUR INSTALL

CONFORME AUX

MAISONS MOB

ETATS-UNIS

TION DE MAISONS MA

CAS OU CETTE NORM

A LA NORME RE

NCENDIE PO

FACTURE

L

GDS

ELEVA

ALIMENTAT

DUCED INPUT /

MENTATION REDUITE

4001657 (NGZ)
4001659 (WUSA)

II

L

HES AN

OPER REINSTA

NECESSARY

HE VENT-AIR INTAKE

IL

I

Advertising
Ce manuel est liée aux produits suivants: