4.5 APPLIANCE VENT CONNECTION

4.6 GAS

INSTALLATION

30.2

Installation and servicing to be done by a qualifi ed installer. Do not use open fl ame.

A.

Move the appliance into position and secure.

B.

If equipped with a fl ex connector the appliance is designed to accept a 1/2” gas supply. Without the
connector it is designed to accept a 3/8” gas supply. The appliance is equipped with a manual shut off
valve to turn off the gas supply to the appliance.

C.

Connect the gas supply in accordance to local codes. In the absence of local codes, install to the
current CAN/CSA-B149.1 Installation Code in Canada or to the current National Fuel Gas Code, ANSI
Z223.1 / NFPA 54 in the United States.

D.

When

fl exing any gas line, support the gas valve so that the lines are not bent or kinked.

E.

Check for gas leaks by brushing on a soap and water solution.

!

WARNING

RISK OF FIRE, EXPLOSION OR ASPHYXIATION. ENSURE THERE ARE NO IGNITION SOURCES SUCH

AS SPARKS OR OPEN FLAMES.

SUPPORT GAS CONTROL WHEN ATTACHING GAS SUPPLY PIPE TO PREVENT DAMAGING GAS LINE.

ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT

WITH THE GLASS DOOR OPENED OR REMOVED. PURGING OF THE GAS SUPPLY LINE SHOULD BE

PERFORMED BY A QUALIFIED SERVICE TECHNICIAN. ASSURE THAT A CONTINUOUS GAS FLOW IS AT

THE BURNER BEFORE CLOSING THE DOOR. ENSURE ADEQUATE VENTILATION. FOR GAS AND

ELECTRICAL LOCATIONS, SEE “DIMENSION” SECTION.

HIGH PRESSURE WILL DAMAGE VALVE. DISCONNECT GAS SUPPLY PIPING BEFORE TESTING GAS

LINE AT TEST PRESSURES ABOVE 1/2 PSIG.

VALVE SETTINGS HAVE BEEN FACTORY SET, DO NOT CHANGE.

28.5A

A.

Attach the adjustable pipe to the last section of rigid pipe. Secure
with screws and seal.

B.

Install the inner fl ex pipe to the appliance. Secure with 3 screws
and fl at washers. Seal the joint and screw holes using the high
temperature sealant W573-0007 (not supplied).

C.

Run a bead of high temperature sealant (not supplied) around the
inside of the air intake collar. Pull the adjustable pipe a minimum 2”
(50.8mm) into the air intake collar.

NOTE: Ensure that the sealant is not visible on the exterior pipes once
installation is completed. An optional decorative black band is available
for this use. In the event that the venting must be disassembled, care
must be taken to reseal the venting.

#8 X 1/2”

SELF

DRILLING

SCREWS

HIGH TEMPERATURE
SEALANT

2” (50.8mm)
OVERLAP