Installation & Servicing Instructions Rinnai E-Series

68

6. Place the drain hose (H3) and the hose (H2) to the pump (CP) inlet into the cleaning

solution.

7. Open both service valves (V1 and V2) on the hot water and cold water lines.
8. Operate the pump (CP) and allow the cleaning solution to circulate through the

brazed plate heat exchanger for at least 45 minutes.

9. Turn off the pump (CP).
10. Rinse the cleaning solution from the brazed plate heat exchanger as follows:

a. Remove the free end of the drain hose (H3) from the pail
b. Close service valve, (V2), and open shutoff valve, (V4). Do not open shutoff

valve, (V3).

c. Disconnect both H1 and H3 from the service valves
d. Connect H3 to V1 and place the end of the hose in a drain
e. Allow water to fl ow through the brazed plate heat exchanger for 5 minutes
f. Close service valve, (V1), and open shutoff valve, (V3).

11. Disconnect all hoses.

Flushing

and

draining

figure

38

T

P

V1

V2

CP

H1

H2

H3

V3

V4

T

P

V1

V2

H1

V3

V4

Flushing

Draining

Low Loss Header

Sediment fi lter

Cold water

Mixed water

to fi xtures

Thermostatic

mixing valve

Vinegar

System Supply

System Return

Low Loss Header

Sediment fi lter

Cold water

Mixed water

to fi xtures

Thermostatic

mixing valve

Drain

System Supply

System Return

Advertising