Installation & Servicing Instructions Rinnai E-Series

37

6.7.4

Recommended vent/air intake terminal position

Terminals should be positioned as to avoid products of combustion entering openings into buildings or other vents.

Maintain 12” of clearance
above the highest
anticipated snow level
or grade or, whichever is
greater. Please refer to
your local codes for the
snow level in your area.

clearances

of

venting

system

terminals

table

6

Terminal positions

figure 15

[1] A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves
both dwellings.
[2] Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the fl oor.
* For clearances not specifi ed in ANSI Z223.1/NFPA 54 or CSA B149.1, clearances are in accordance with local installation codes and the
requirements of the gas supplier.

Ref

Description

Canadian Installations - Direct Vent

and non Direct Vent

US Installations Direct Vent

US Installations

non Direct Vent

A Clearance above grade, veranda, porch,

deck, or balcony

12 inches (30 cm)

12 inches (30 cm)

12 inches (30 cm)

B Clearance to window or door that may

be opened

6 inches (15 cm) for appliances < 10,000

Btuh (3 kW), 12 inches (30 cm) for

appliances > 10,000 Btuh (3 kW) and <

100,000 Btuh (30 kW), 36 inches (91 cm)

for appliances > 100,000 Btuh (30 kW)

6 inches (15 cm) for appliances <

10,000 Btuh (3 kW), 9 inches (30 cm) for

appliances > 10,000 Btuh (3 kW) and <

50,000 Btuh (30 kW), 12 inches (91 cm)

for appliances > 50,000 Btuh (30 kW)

4 feet (1.2 m) below or to

side of opening; 1 foot (300

mm) above opening

C Clearance to permanently closed window

*

*

*

D Vertical clearance to ventilated soffi t,

located above the terminal within a
horizontal distance of 2 feet (61 cm) from
the center line of the terminal

*

*

*

E Clearance to unventilated soffi t

*

*

*

F Clearance to outside corner

*

*

*

G Clearance to inside corner

*

*

*

H Clearance to each side of center

line extended above meter/regulator
assembly

3 feet (91 cm) within a height 15 feet (4.5

m) above the meter/regulator assembly

*

*

I

Clearance to service regulator vent outlet

36 inches (91 cm)

*

*

J Clearance to nonmechanical air supply

inlet to building or the combustion air inlet
to any other appliance

6 inches (15 cm) for appliances < 10,000

Btuh (3 kW), 12 inches (30 cm) for

appliances > 10,000 Btuh (3 kW) and <

100,000 Btuh (30 kW), 36 inches (91 cm)

for appliances > 100,000 Btuh (30 kW)

6 inches (15 cm) for appliances <

10,000 Btuh (3 kW), 9 inches (30 cm) for

appliances > 10,000 Btuh (3 kW) and <

50,000 Btuh (30 kW), 12 inches (91 cm)

for appliances > 50,000 Btuh (30 kW)

4 feet (1.2 m) below or to

side of opening; 1 foot (300

mm) above opening

K Clearance to a mechanical air supply

inlet

6 feet (1.83 m)

3 feet (91 cm) above if within 10 feet (3

m) horizontally

3 feet (91 cm) above

if within 10 feet (3 m)

horizontally

L Clearance above paved sidewalk or

paved driveway located on public
property

7 feet (2.13 m) [1]

*

7 feet (2.13 m)