PC 45 Corn/Pellet Stove

Venting

Requirements for Terminating the Venting

WARNING: Venting terminals must not be re-

cessed into a wall or siding.

NOTE: Only PL vent pipe wall pass-throughs

and fire stops should be used when venting through
combustible materials.

NOTE: Always take into consideration the ef-

fect the prevailing wind direction or other wind cur-
rents will cause with flyash and /or smoke when plac-
ing the termination.

In addition, the following must be observed:
A. The clearance above grade must be a mini-

mum of 18".

1

B. The clearance to a window or door that may

be opened must be a minimum of 48" to the side,
48" below the window/door, and 12" above the win-
dow/door.

1

(

with outside air installed, 18” )

C. A 12" clearance to a permanently closed

window is recommended to prevent condensation
on the window.

D. The vertical clearance to a ventilated soffit

located above the terminal within a horizontal dis-
tance of 2 feet (60 cm) from the center-line of the
terminal must be a minimum of 18".

E. The clearance to an unventilated soffit must

be a minimum of 12".

F. The clearance to an outside corner is 11"

from center of pipe.

G. The clearance to an inside corner is 12".
H. A vent must not be installed within 3 feet (90

cm) above a gas meter/regulator assembly when
measured from the horizontal center-line of the regu-
lator.

1

I. The clearance to service regulator vent outlet

must be a minimum of 6 feet.

1

J. The clearance to a non-mechanical air sup-

ply inlet to the building or the combustion air inlet to
any other appliance must be a minimum of 48”.

1

K. The clearance to a mechanical air supply

inlet must be a minimum of 10 feet.

1

(with outside air installed, 6 feet )
L. The clearance above a paved sidewalk or a

paved driveway located on public property must be
a minimum of 7 feet.

1,2

M. The clearance under a veranda, porch, deck

or balcony must be a minimum of 12 inches.

1,3

NOTE: The clearance to vegetation and other

exterior combustibles such as mulch is 36” as mea-

sured from the center of the outlet or cap. This 36”
radius continues to grade or a minimum of 7 feet
below the outlet.

1

Certain Canadian and or Local codes or regu-

lations may require different clearances.

2

A vent shall not terminate directly above a side-

walk or paved driveway which is located between
two single family dwellings and serves both dwell-
ings.

3

Only permitted if veranda, porch, deck, or bal-

cony is fully open on a minimum of 2 sides beneath
the floor.

NOT E: Where passa ge t hrough a w all, or
partition of combustible construction is desired,
the installation shall conform to CAN/CSA-B365.
(if in Canada)