Installation

Installing

Place the stove on a noncombustible floor protec-

tor that extends 6 inches to the front, 6 inches to the
sides and 1 inch to the rear of the stove. The minimum
floor protector material is 24 gauge sheet metal.

Place the stove away from combustible walls at least

as far as shown in figures 6,7 & 8. Please note the differ-
ence in side wall clearance with and without side shields.

Note that the clearances shown are minimum for

safety but do not leave much room for access when clean-
ing or servicing. Please take this into account when plac-
ing the stove.

Connect the power cord to a 120 V.A.C. 60Hz

grounded receptacle. (A surge protector is recommened
to protect the circuit board).

Prior to installing the flue pipe, connect a draft meter

to the stove as shown in fig. 9. (The draft meter must
have a minimum range of 0"- 0.5"). Turn stove to "TEST"
Mode and record the draft reading ______. After the flue
pipe is connected, check the draft reading again making
sure all doors and windows in the home are closed. If
this reading is more than.05" higher than the unconnected
reading, check for possible restrictions or the need for
outside air. (See page 8).

Mobile Home Installation

When installing this unit in a mobile home several

requirements must be followed:

1. The unit must be bolted to the floor. This can be done

with 1/4" lag screws through the 2 holes in the base plate.

2. The unit must also be connected for the outside

air. See page 8.

3. Floor protection and clearances must be followed

as shown.

4. Unit must be grounded to the metal frame of the

mobile home.
CAUTION: This appliance must be vented to the out-
side.

Due to high temperatures, the stove should be placed out of traffic

and away from furniture and draperies.

Children and adults should be alerted to the haz-

ards of high surface temperatures and should stay away
to avoid burn to skin and/or clothing.

Young children should be carefully supervised when

they are in the same room as the stove.

Clothing and other flammable materials should not

be placed on or near this unit.

Installation and repair of this Harman Stove should

be done by a qualified service person. The appliance
should be inspected before use and at least annually by a
qualified service person. More frequent cleaning will be
required. It is imperative that control compartments, burn-
ers, and circulating air passageways of the stove be kept
clean.
Mobile home installation should be done in accordance
with the Manufactured Home and Safety Standard (HUD),
CFR 3280, Part 24.