Venting, 7 installing through the ceiling vent, Caution – Harman Stove Company PC 45 Manuel d'utilisation

Page 12: Warning caution

Advertising
background image

12

PC 45 Corn/Pellet Stove

Fig. 18

No insulation or
other combustible
ma te ri al s

ar e

allowed within 3"
of the P L ve nt
pipe.

PL vent manufacturer's
fi re stop s pa ce r an d
support

(See Page 6 for
corner installation
clearances)

Minimum flue vent configuration

It is rec omme nde d that

outside air be installed with this
venting configuration.

M

in

.

a

b

o

v

e

g

ro

u

n

d

le

v

e

l

1

2

"

Storm collar

Flashing

3" min.

3" min.

12" min.

3" min.

Venting

Fig. 19

Fig. 20

#7 Installing through the ceiling vent

Thr ough the c eiling vent, f ollo w PL vent

manufacturers recommendations when using wall and
ceiling pass through.

DO NOT INSTALL A FLUE DAMPER IN THE
EXHAUST VENTING SYSTEM OF THIS UNIT.

DO NOT CONNECT THIS UNIT TO A CHIMNEY
FLUE SERVING ANOTHER APPLIANCE.

INSTALL VENT AT CLEARANCES SPECIFIED
BY THE MANUFACTURER

CAUTION

DO NOT INSTALL IN SLEEPING ROOM

WARNING

CAUTION

THE STRU CTURAL INTEGRITY OF TH E
MOBILE HOME FLOOR, WALL, AND CEILING/
ROOF MUST BE MAINTAINED.

THE STOVE IS HOT WHILE IN OPERATION.
KEEP C HILD REN,

C LO TH IN G AN D

FURNITURE AWAY. CONTACT MAY CAUSE
SKIN BURNS.