Automatic ignition esp control, Status light error message – Harman Stove Company PC 45 Manuel d'utilisation

Page 17

Advertising
background image

17

PC 45 Corn/Pellet Stove

AUTOMATIC IGNITION ESP CONTROL

Feed adjuster
Sets the maximum
feed rate

Test
Runs all motors at full
speed for one minute
to check operation.
After two minutes the
s to ve wil l go to
minimum burn and
the b lo we rs wil l
alternate from high to
low every minute to
remind you that you
a re s ti ll i n "Tes t
Mode".

Igniter switch
Set to appropriate
Start-Up mode.

Di stri bu ti on B lo we r
speed adjustment range.
L = low
H = high
Variable speed anywhere
b etwe en L a nd H;
although as the stove
temp. goes up , so does
the L and H scale.

Temp dial
Allows you to adjust the room temperature in Room
Temp Mode using the outer scale marked in degrees
Fahrenheit. It also allows you to adjust the stove
temperature while in Stove Temp Mode using the inner
scale marked from 1 to 7.

Mode Selector
A ll ows yo u to c ho os e
between Room Temp Mode,
Stove Temp Mode, or OFF.
Also allows you to vary the
distribution blower speed by
turning the knob to the high
or low side of each mode.

Power Light
Indicates power to the
control.

Indicates power to the
feed motor.

Indicates

igniter

is on.

Indicates power to
combustion blower

Status Light
Will be lit in either stove
or room temp mode when
pointer is not within off
position band except
after normal shut down.
Blinks to indicate errors
listed below.

Indicates power to
distribution blower.

6 Blinks : Indicates that the control has calculated
poor or incomplete combustion occurring for more
than 50 minutes. See Troubleshooting section for
more details.
A six blink status may be set if the stove is allowed
to run out of pellets. To reset, turn mode selector to
"OFF" then back on to the desired mode. If the unit
was not out of pellets, see Troubleshooting section,
Page 24, for more details.
* Manual reset- Disconnect power cord for a few
seconds and reconnect. If error still occurs call your
Harman Dealer.

Status light error message

s:

1 Blink: Indicates control board self diagnostic fail-
ure. This requires a manual reset*.
3 Blinks: Indicates ESP (Exhaust Sensing Probe)
failure. This requires a manual reset*.
4 Blinks: Can occur only in Room Temp Mode and
indicates Room Sensing Probe failed or not installed.
If a Room Sensing Probe is then installed, the sta-
tus light will automatically reset.
NOTE: Unit will not start in "AUTO" with this status
error.
5 Blinks (In Igniter Auto. Mode Only): Indicates
that the unit has failed to light within the 45 minute
start cycle. To reset - Turn Mode Selector to "OFF",
then turn to either mode again.

Dealer Diagnostic Port
For dealer maintenance use
only. Requires special DDM
monitor supplied to Harman
Dealers exclusively.