PC 45 Corn/Pellet Stove

Fig. 16

Venting

#5 Installing into an existing

fireplace chimney (US and Canada)

This method provides excellent venting for nor-

mal operation. This method also provides natural
draft in the event of a power failure.

In Canada and some places in the US it is

required that the vent pipe extend all the way to the
top of the chimney.

In this method a cap should also be installed

on the chimney to keep out rain. Be sure to use
approved pellet vent pipe fittings. Seal pipe joints
with silicone in addition to the sealing system used
by the manufacturer. Pipe size should be increased
to 4" using this method.

#6 Installing into an existing

chimney ( US and Canada )

This method provides excellent venting for nor-

mal operation. This method also provides natural
draft in the event of a power failure.

In Canada and some places in the US it is re-

quired that the vent pipe extend all the way to the top
of the chimney. The pipe or liner inside the chimney
should be 4"diameter.

In this method a cap should also be installed

on the chimney to keep out rain.

Fig. 17