Chapter 11 : RS-232 PROGRAMMER'S GUIDE (continued)

PAGE 21

11-4. COMMANDS AND RESPONSES TABLE

The following table resumes commands, which are recognized as valid, and the responses that will be returned to the
control device (on RS-232 port).

ASCII

RESPONSE

COMMAND

TYPE

VALUE

COMMAND

DESCRIPTION

MIN MAX

DESCRIPTION

FRONT PANEL COMMANDS

z

FRZ

FREEZE.

Rd/Wr

0

1

1 = image freeze.

a

ASP

Size mode selection.

Rd/Wr

0

2

0 = 4/3.
1 = 16/9.
2 = ZOOM.

h

HP

Horizontal position adjustment.

Rd/Wr

0

255

v VP

Vertical

position

adjustment. Rd/Wr

0

255

w HW

Horizontal

size

adjustment. Rd/Wr

0

255

s

VS

Vertical size adjustment.

Rd/Wr

0

255

H

ZHP

Zoom horizontal position.

Rd/Wr

0

255

V

ZVP

Zoom vertical position.

Rd/Wr

0

255

W

ZHW

Zoom horizontal size.

Rd/Wr

0

255 0 = 100%

255 =200%

S

ZVS

Zoom vertical size.

Rd/Wr

0

255 0 = 100%

255 =200%

R

REC

RECALL.

Rd/Wr

0

1

1 = recall (automatic reset)

M

STO

STORE.

Rd/Wr

0

1

1 = store (automatic reset)

INPUT COMMANDS

GP

REFP

Genlock H phase adjustment

Rd/Wr

0

65535

E

SOGI

SOG input selection.

Rd/Wr

0

1

0 = no

1 = yes.

l

LOAD

H sync load selection.

Rd/Wr

0

1

0 = Hi-Z

1 = 75 ohms.

OUTPUT COMMANDS

F

OFMT

Output format selection

Rd/Wr

0

7

0 = 720p @ 59.94Hz 4 = 1080i @ 50Hz
1 = 720p @ 60Hz

5 = 1080i @ 59.94Hz

2 = 1035i @ 59.94Hz 6 = 1080i @ 60Hz.
3 = 1035i @ 60Hz

GR REFR

Synchronization

mode

selection. Rd/Wr

0

2

0

=

internal.

1 = genlock.

e

OSYN

Sync type selection. Rd/Wr

0

1

0

=

tri-levels.

1 = bi-levels.

P

OPAT

Test pattern selection.

Rd/Wr

0

1

0 = no test pattern.
1 = test pattern selected.

IMAGE COMMANDS

f

FLK

Flicker level selection.

Rd/Wr

0

7

k

BLK

Black level adjustment

Rd/Wr

0

255

r

RLV

Red level adjustment.

Rd/Wr

0

127

g GLV

Green

level

adjustment.

Rd/Wr

0

127

b

BLV

Bleu level adjustment.

Rd/Wr

0

127

o OVR

Under/overscan

mode

selection.

Rd/Wr

0

1

0 = underscan

1 = overscan

L

HSMT

Horizontal smooth

Rd/Wr

0

1

0 = OFF

1 = ON.

yp

PRES

PRESET

Rd/Wr

0

1

1 = PRESET (automatic reset).

CONTROLS COMMANDS

yl

LOCK

Front panel locking selection.

Rd/Wr

0

1

0 = unlock

1 = lock.

yc

EPOS

Erase memory.

Rd/Wr

0

1

1 = erase all memories (automatic reset).

Y

FRES

Default value.

Rd/Wr

0

1

1 = set all the parameters to the default value
(automatic reset).

xk

K_

K internal version

Rd

0

65535

xs

S_

S internal version

Rd

0

65535

xf

F_

F internal version

Rd

0

65535

xi I_

Identification

number.

Rd

0

65535

yo

OPT

HD SCAN options.

Rd

0

65535

Z

IFRM

Freeze mode

Rd/Wr

0

1

0 = slow

1 = fast.

NOTE: Rd = Read only command.