Pulse/manual seal mode – Weston Pro Advantage Vacuum Sealer Manuel d'utilisation
Page 10

PULSE/MANUAL SEAL MODE
The
PULSE Button manually controls the
vacuum pressure when using vacuum bags to
vacuum and seal liquids, moist and/or delicate
foods to ensure that liquid does not enter
the
Vacuum Chamber or that the item does
not crush.
NOTE: The pulse function will not
evacuate all air from the vacuum bags.
1. Attach the
Vacuum Sealer to the power
supply.
2. Press the
ON/OFF Button (Figure 10) on the Control Panel to turn the Vacuum
Sealer “ON”. The ON/OFF Button on the display will illuminate and the Internal
Cooling Fan will run.
3. Press both of the
Lid Release Buttons on each side of the Vacuum Sealer to
release the lid lock, then lift the
Vacuum Lid to open.
4. Fill the vacuum bag with the product to be vacuum sealed. The open end of the
vacuum bag must be clean and dry to seal properly.
HINT: When filling bags, fold over
the top portion of the bag, fill the bag, then unfold the top portion to seal.
5. Place the open end of the bag onto the
Vacuum Chamber Seal and slightly into the
Vacuum Chamber. The Vacuum Post cannot be blocked or covered by the bag. Make
sure there are no wrinkles or creases in the bag in the sealing area.
6. Push down and close the
Vacuum Lid and lock into place. The open end of the
bag should be sandwiched between the
Seal Bar Insulator and the Seal Bar Heating
Element/Seal Bar Tape.
7. Press the
PULSE Button (Figure 10) once. Then press and hold the PULSE Button
until the desired amount of air is evacuated from the bag.
8. Press the
SEAL Button, this will engage the Vacuum Pump and Seal Bar Heating
Element and seal the vacuum bag. The SEAL Button on the display will illuminate while
sealing. The appliance will stop automatically and “BEEP” when the seal process is complete.
9. DO NOT try to open the
Vacuum Lid before the vacuum has released or damage
may occur. Press both of the
Lid Release Buttons on each side of the Vacuum Sealer
to release the lid lock, then lift the
Vacuum Lid to open.
10. Remove the vacuum sealed bag. Wait at least 20 seconds before sealing another bag
to avoid overheating the unit.
11. Press the
ON/OFF Button on the Control Panel to turn the Vacuum Sealer “OFF”.
12. Disconnect the
Vacuum Sealer from the
power supply.
Figure 10
Control Panel
REMPLACEMENT DE LA
GARNITURE
DU COUVERCLE :
1. Appuyer sur la touche ON/OFF du
tableau de commande pour éteindre la
scelleuse sous vide.
2. Débrancher la scelleuse de la source
d’alimentation.
3. S’assurer que la scelleuse a
entièrement refroidi.
4.
Enfoncer les deux boutons
déclencheurs du couvercle de chaque côté
de la scelleuse pour libérer le verrou, puis
ouvrir le couvercle.
5. Retirer la garniture de la gorge dans
le socle en plastique du couvercle (Figure
18).
REMARQUE : Le dos de la garniture du
couvercle est adhésif : en cas de difficulté
à décoller la garniture du plastique, utiliser
un dissolvant ménager doux d’adhésif.
S’assurer que la surface est sèche et
exempte d’huile avant de mettre en place
une garniture de couvercle neuve.
6. Retirer la pellicule protectrice de la
garniture du couvercle. Loger la garniture
neuve dans la gorge du socle en plastique
du couvercle.
7. Étendre la garniture avec les doigts, puis la pousser contre la gorge 30 secondes
pour la loger parfaitement. Patienter 30 minutes avant d’utiliser l’appareil.
REMPLACEMENT DE L’ENSEMBLE COUVERCLE :
1. Appuyer sur la touche ON/OFF du tableau de commande pour éteindre la
scelleuse sous vide.
2. Débrancher la scelleuse de la source d’alimentation.
3. S’assurer que la scelleuse a entièrement refroidi.
4. Enfoncer les deux boutons déclencheurs du couvercle de chaque côté de la
scelleuse pour libérer le verrou, puis ouvrir le couvercle.
5. Dévisser le socle en plastique du couvercle (4 vis) avec un tournevis Phillips
(Figure 19).
REMARQUE : Les tournevis courts, de petit diamètre ou coudés, sont les plus
efficaces à cet effet.
Figure 18
Isolant de
la bande de
scellement
Socle en plastique du couvercle
Vis
Figure 19
-10-
-35-