Chapter 4: Performance Features & Safety Precautions

Product Service 1-800-522-7658

46

Original instructions

4.

Intelligent filter identification indicates type (HEPA or Neutrodine) and

status (primary or secondary) to prevent saturated filter reinstallation risk.

5.

Identification card is required for operation to control access to specified

users.

6.

Available with gGuard

software to monitor, manage and provide data

via email to a designated facility manager.

7.

SEFA 9 Compliant as a DH3. Passes AFNOR NF-X 15-211.


The Benefits of Fume Hood Technology

8.

Patented* Clean-Sweep™ Sash Handle and Sash Tracks and Eco-

Foil™ Air Foil maximize containment.

9.

Corrosion-resistant panelized fiberglass liner with option for glass sides

and back provide durability for long life.

10.

Fully-closing, vertical-rising sash opens to 28" high for loading. No

hinges to impair visibility.

11.

Operating Height of 16" high for energy savings with defeatable sash

stop. Sash Stop adjustable to other heights such as 10" through 18" to
meet 100 feet per minute local requirements when needed.

12.

31" deep interior working space

13.

Maintains 60-100 fpm face velocity but, unlike traditional hoods, has no

ducted exhaust requirements.

14.

Accommodates up to four electrical duplex receptacles and eight

services fixtures.

15.

Available in 37.7" depth and 4', 5', 6' and 8' widths.

16.

Passes ASHRAE 110-1995 Fume Hood Containment Tests.

17.

By-pass airflow design ensures relatively stable face velocities.

18.

Large usable interior work depth and interior height of 48" provides

ample working space.

19.

Exterior access cover plates are removable for easy access to plumbing

valves and sash adjustment hardware when access through the sides is not
available.

20.

Lift-Away™ front, side, and rear panels provide easy access to

electrical wiring, sash weights, and lighting fixtures.

21.

Energy efficient fluorescent lighting is located behind a plastic shield.

The factory-wired instant start lighting is serviceable from outside the
hood cavity and provides up to 63 foot candles inside the work area.

22.

Eco-Foil Air Foil allows air to sweep the work surface for maximum

containment. Flush foil is also available. The air foils have Clean-
Sweep™ openings that create a constant barrier from contaminants. In
addition, should the operator inadvertently block the airflow entering, the
air continues to enter from under the air foil and through the Clean-Sweep
openings.

23.

Streamlined corner posts provide maximum visibility and the flexibility

to add services after installation.

24.

All hoods are factory prepared for up to 8 service fixtures.

25.

Duplex electrical receptacles are mounted on the right and left corner

posts as requested. Receptacles are factory-wired to hood single point
junction boxes.