5. Connect the RPT Adapter Kit wire harness connector to the receptacle on the Power Supply torch connection

panel. Turn the locking ring to secure the connector to the torch connection panel.

6. Ensure that there is no strain on any of the connections. Secure the Strain Relief Dome Nut to the Strain Relief

by hand. Do not over-tighten.

7. Reinstall the Power Supply cover.

C. Operation

1. Connect primary input power. Turn on the gas supply.

2. Set proper gas pressure and flow per the Torch Instruction Manual.

3. Test for proper operation.

D. Pinout Diagram

1

2

3

4

Black / PIP

White / Switch

Green / Switch

Orange / PIP

Front View of Connector

Art # A-03965

NOTE

Every effort has been made to provide complete and accurate information in this manual. However, the
publisher does not assume and hereby disclaims any liability to any party for any loss or damage caused
by errors or omissions in this Manual, whether such errors result from negligence, accident, or any other
cause.