SERVICE

5-6

Manual 0-2731

J . GAS indicator OFF

1. Gas pressure set too low

a. Adjust pressure

2. Faulty power supply

a. Isolate and replace component(s) per Service

Manual.

3. No coolant flow.

a. Return for repair or have qualified technician repair

per Service Manual.

K. GAS indicator OFF, plasma and/or secondary gas does

not flow

1. Low plasma pressure

a. Check plasma pressure

2. Secondary supply turned OFF (or cylinder empty)

a. Check secondary supply

3. Secondary Selector switch set to wrong position

a. Check and set switch to proper type of secondary

being used

4. Blocked torch

a. Check torch parts.

5. Faulty power supply

a. Isolate and replace component(s) per Service

Manual.

L. GAS Indicator flashing ON and OFF

1. Air in coolant lines

a. Run pump for ten minutes to purge air from

the coolant lines before using the system.

2. Coolant Level is low

a. Check for proper coolant level at rear panel

gauge

M. Leaking torch connection

1. Loose torch connection

a. Check connection making sure connector is

fully seated.

N. Weak or sputtering pilot; HF stays on during pilot

1. Plasma gas pressure too high

a. Adjust pressure

2. Low OCV (normal 290-350 VDC) caused by improper

input voltage selection

a. Check input voltage connections

3. Faulty power supply

a. Isolate and replace component(s) per Service

Manual.

O. Pilot arc ON; No main arc transfer (torch brought

within range of work)

1. Work cable not connected

a. Connect work cable securely

2. Faulty power supply

a. Isolate and replace component(s) per Service

Manual.

3. Faulty Optional Remote Arc Starter

a. Refer to 'Troubleshooting With Optional Re-

mote Arc Starter' below

P. AC indicator ON; GAS indicator light ON; torch is

activated; DC indicator light blinks

1. Shorted torch.

a. Isolate and replace component(s) per Torch

Manual.

2. Faulty power supply.

a. Isolate and replace component(s) per Service

Manual.

Troubleshooting With Optional Remote Arc

Starter

NOTE

The following troubleshooting is to be used only if
the system has the Optional Remote Arc Starter
installed.

Q. Start signal given to the Power Supply. Gas flows

for selected pre-flow time. DC indicator is OFF,
does not even come ON momentarily.

1. Problem not in the Remote Arc Starter. The Power Sup-

ply is has no DC voltage output.

a. Refer to the Power Supply Service Manual to test

the output of the Power Supply