3.10 Optional Remote Arc Starter

A. Mounting Arc Starter Box

Mount the Arc Starter Box to the cutting table gantry as
follows:

1. Remove the four screws securing the cover to the base

assembly of the Arc Starter Box.

Screws

(Four Places)

A-02279

Figure 3-14 Cover Screw Removal

2. Slide the cover up and off the base assembly.

A-02280

Base Assembly

Cover

Figure 3-15 Cover Removal

3. Mount the base assembly of the Arc Starter Box to the

cutting table gantry using the four holes provided in
the base.

NOTE

The last page of this Manual has a full size hole
template for use in locating the mounting holes.

Four Mounting Bolts And

Washers (Customer Supplied)

A-02281

Base

Assembly

To Plasma

Power Supply

To Torch

Figure 3-16 Mounting Bolt Installation

B. Connecting Torch

WARNING

Disconnect primary power at the source before
disassembling the torch or torch leads.

CAUTION

This system is designed for use with the Maximizer
300 Torch only. Do not connect any other torch to
this power supply.

The Torch Leads connect directly to a bulkhead inside the Re-
mote Arc Starter. Connect the Torch Leads as follows:

1. Remove the cover from the Remote Arc Starter if in-

stalled.

2. Remove the hardware attached to the ends of the Torch

Leads assembly with a wire tie.

3. Feed the torch leads through the boot on the torch end

of the Remote Arc Starter.

4. Connect the torch leads connectors to the bulkhead

connections per the following figure.