10 optional remote arc starter, 10 optional remote arc starter -13 – Tweco 1000 CE Merlin Manuel d'utilisation
Page 31

Manual 0-2731
3-13
INSTALLATION
3.10 Optional Remote Arc Starter
A. Mounting Arc Starter Box
Mount the Arc Starter Box to the cutting table gantry as
follows:
1. Remove the four screws securing the cover to the base
assembly of the Arc Starter Box.
Screws
(Four Places)
A-02279
Figure 3-14 Cover Screw Removal
2. Slide the cover up and off the base assembly.
A-02280
Base Assembly
Cover
Figure 3-15 Cover Removal
3. Mount the base assembly of the Arc Starter Box to the
cutting table gantry using the four holes provided in
the base.
NOTE
The last page of this Manual has a full size hole
template for use in locating the mounting holes.
Four Mounting Bolts And
Washers (Customer Supplied)
A-02281
Base
Assembly
To Plasma
Power Supply
To Torch
Figure 3-16 Mounting Bolt Installation
B. Connecting Torch
WARNING
Disconnect primary power at the source before
disassembling the torch or torch leads.
CAUTION
This system is designed for use with the Maximizer
300 Torch only. Do not connect any other torch to
this power supply.
The Torch Leads connect directly to a bulkhead inside the Re-
mote Arc Starter. Connect the Torch Leads as follows:
1. Remove the cover from the Remote Arc Starter if in-
stalled.
2. Remove the hardware attached to the ends of the Torch
Leads assembly with a wire tie.
3. Feed the torch leads through the boot on the torch end
of the Remote Arc Starter.
4. Connect the torch leads connectors to the bulkhead
connections per the following figure.