Tweco 1000 CE Merlin Manuel d'utilisation
Page 29

Manual 0-2731
3-11
INSTALLATION
A. Computer Control Interface (CNC)
NOTE
Used when Standoff Control SC11 are not used.
The computer control interface (CNC) allows an auto-
mated system to interface with a computer or other control
device.
CNC cables can be interfaced to the Power Supply using one of
the following methods:
NOTE
Refer to Appendix 6 for CNC Interface Schematic.
• Connector (J22) at the rear of the Power Supply
• Internal terminal block in the Power Supply
Depending on the equipment ordered and the cables supplied
connect the CNC cable per one of the following:
1. Using supplied CNC cable
Connect the supplied Power Supply/CNC Cable
to the Power Supply rear panel connector J22 (CNC
Control).
A-02858
J22
CNC Connector
CNC or Remote Hand
Pendant Control Cable
Figure 3-10 Using CNC Connector (J22)
2. Using customer supplied CNC Cable
a. Remove the Right Side Panel from the Power Sup-
ply as viewed from the front of the unit.
b. Remove the 7/8" knockout from the Rear Panel and
install a 1/2" NPT strain relief (not supplied) into
the hole.
A-02859
CNC Knockout
1/2" (12.7 mm)
Strain Relief
(Customer Supplied)
Figure 3-11 Rear Panel Knockout Location
c. Locate the internal terminal block (TB) on the Fil-
ter/Voltage Divider PC Board, located on the inside
of Rear Panel below the WATER Secondary con-
nection. The terminal block (TB) is plugged into a
socket on the Filter/Voltage Divider PC Board.
d. Feed the CNC cable (see NOTE) through the strain
relief at the rear of the Power Supply, routing the
cable above the existing wiring to the Terminal Block
(TB) on the Filter/Voltage Divider PC Board.
NOTE
The CNC Cable to TB connections must be rated
at 600V.
e. Remove the terminal block from the socket and con-
nect the CNC cable to the terminal block (TB) per
the following chart (see NOTES after chart):