Section 5: service, 01 introduction, 02 general maintenance – Tweco 1000 CE Merlin Manuel d'utilisation

Page 45: Section 5, Service -1, 01 introduction -1 5.02 general maintenance -1

Advertising
background image

Manual 0-2731

5-1

SERVICE

SECTION 5:

SERVICE

5.01 Introduction

This section describes maintenance procedures, basic
troubleshooting and service performable by operating
personnel. No other adjustments or repairs are to be at-
tempted by other than properly trained personnel.

For major troubleshooting and parts replacement pro-
cedures refer to Merlin 1000 Power Supply Service
Manual 0-2732.

5.02 General Maintenance

A. Routine Maintenance

NOTE

Refer to Appendix 9 for a recommended mainte-
nance schedule for water cooled plasma cutting
systems.

Routine maintenance for the Power Supply should in-
clude an occasional thorough cleaning and inspection. The
frequency depends on the usage and the operating envi-
ronment.

WARNING

Disconnect primary power at the source before as-
sembling or disassembling power supply, torch
parts, or torch and leads assemblies.

B. Power Supply Cleaning

To clean the unit, open the enclosure and use a vacuum
cleaner to remove any accumulated dirt and dust. The
unit should also be wiped clean. If necessary, solvents
that are recommended for cleaning electrical apparatus
may be used. Do NOT blow air into the power supply
during cleaning; make sure to always blow air out of the
unit. Blowing air into the unit can cause metal particles
to interfere with sensitive electrical components and cause
damage to the unit.

While the side panels are off, inspect the wiring in the
unit. Look for any frayed wires or loose connections that
should be corrected.

C. Coolant Filter Assembly

The filter screen should be cleaned periodically. Remove
the filter screen by unscrewing the filter holder from the
Coolant Filter Assembly on the rear panel. Clean the fil-
ter screen by rinsing with hot soapy water. Remove soap
residue by rinsing with clean hot water. Be sure that all
the soap has been removed and the screen is dry of water
before re-installing in the Coolant Filter Assembly.

A-02152

Filter Holder

Filter

Figure 5-1 Coolant Filter Assembly

D. In-Line Filter Assembly

The in-line filter screen should be cleaned periodically.
To gain access to the In-Line Filter Assembly remove the
right side panel (viewed from the front of unit) of the
Power Supply. Remove the filter screen by unscrewing
the filter holder from the In-Line Filter Assembly. Clean
the filter screen by rinsing with hot soapy water. Remove
soap residue by rinsing with clean hot water. Be sure
that all the soap has been removed and the screen is dry
of water before re-installing in the In-Line Filter Assem-
bly.

A-02153

Filter Holder

Filter

Figure 5-2 In-Line Filter Assembly

Advertising