INTRODUCTION

2-4

Manual 0-2731

1. Parts-In-Place (PIP) Interlock

The Power Supply has a built-in parts-in-place in-
terlock that prevents accidental torch starting
when torch parts are not properly installed. A flow
switch on the coolant return lead detects reduced
coolant flow caused by improper torch assembly.
If not satisfied, the switch interrupts power to the
tip and electrode.

2. Gas Pressure Interlock

A pressure switch acts as an interlock for the
plasma gas supply. If the plasma gas supply pres-
sure falls below minimum requirements the pres-
sure switch will open, shutting off the power to
the contactors, and the GAS indicator will go out.
When adequate plasma supply pressure is avail-
able the pressure switch will close, allowing power
to be resumed for cutting.

NOTE

There is no gas pressure interlock for sec-
ondary gas.