Tweco 1000 CE Merlin Manuel d'utilisation

Page 24

Advertising
background image

INSTALLATION

3-6

Manual 0-2731

b. Connect the gas supply hose from the secondary gas

supply directly to the input fitting on the rear panel of
the Power Supply marked SECONDARY.

PLASMA GAS

Fitting

SECONDARY

GAS Fitting

Plasma Gas

Hose

Unused Secondary

Air Hose

(End must be plugged)

A-02350

Plasma Air Supply Hose

(Customer Supplied)

Two-Stage

Air Filter

Barb Fitting

Secondary Gas

Hose From Gas

Cylinder

Figure 3-5 Gas Connections Using Shop Air and High-

Pressure Gas Cylinder

c. Connect the air supply hose (see note) to the Air Line

Filter input port (IN) barb fitting and secure with a cus-
tomer supplied hose clamp.

NOTE

The supply hose must be 1/4 inch (6.3 mm) mini-
mum inside diameter to provide adequate air flow.

D. Using Water Secondary

NOTES

Tap water should only be used as a secondary on
machine torches.

The tap water source does not need to be deionized,
but in water systems with extremely high mineral
content a water softener is recommended.

Tap water with high levels of particulate matter
must be filtered.

Tap water can be used instead of a secondary gas and is
connected to the Power Supply as follows:

1. The tap water source must be capable of delivering a

minimum water pressure of 50 - 100 psi (3.5 - 6.9 bar)
and flow of 9 gph (34 lph).

2. Connect the tap water supply hose to the input of a

Water Pressure Regulator.

3. Connect the output of the water regulator to the fitting

marked SECONDARY H2O (water) on the rear panel
of the Power Supply.

A-02351

Water Supply Hose

(Customer Supplied)

WATER

Secondary

Figure 3-6 Secondary Water Connection

Advertising