14. Coolant Reservoir Capacity

2 gallons (Use Thermal Arc

®

coolant only)

Capable of handling a total of 150 feet of torch lead
length

15. Secondary Water

Clean drinking quality tap water can be used as a
secondary and must be capable of delivering the fol-
lowing minimums:

• Water pressure of 50 - 100 psi (3.5 - 6.9 bar)

• Flow of 9 gph (34 lph)

16. Overall Dimensions

Height: 40-1/2 inches (1.03 m)

Width: 20-1/2 in (0.52 m)

Depth: 30-1/4 inches (0.77 m)

17. Weight

Power Supply with Torch: 275 lbs (125 kg)

2.04 Power Supply Options and

Accessories

The following accessories are available for this Power Sup-
ply. Refer to Section 6, Parts Lists, for part numbers and
ordering information.

A. High Pressure Regulators

High pressure regulators are available for air, oxygen,
argon-hydrogen and nitrogen. The regulators are used
to set the proper pressure for the type of gas being
used.

B. Standoff Control (SC11)

Optional Standoff Control automatically finds height
and maintains torch standoff with a high speed torch
lifter motor. Refer to Standoff Control (SC11) Manual,
0-2556, for more information.

C. Remote Arc Starter

Option available to remote the arc starting circuits
closer to the Torch Head Assembly. The option in-
cludes a Remote Arc Starter and Torch Supply Leads.
The Torch Supply Leads are available in 25 ft (7.6 m)
to 100 ft (30.5 m) lengths.

D. Remote Pendant Control

Control used to manually start and stop cutting op-
erations from a location up to 20 ft (6.1 m) from the
Plasma Power Supply.

2.05 Theory Of Operation

A. Plasma Arc Cutting and Gouging

Plasma is a gas which is heated to an extremely high tem-
perature and ionized so that it becomes electrically con-
ductive. The plasma arc cutting process uses this plasma
gas to transfer an electric arc to a workpiece. The metal
to be cut is melted by the intense heat of the arc and then
blown away by the flow of gas.

With a simple change of torch parts, the system can also
be used for plasma arc gouging. Plasma arc gouging uses
the same process to remove material to a controlled depth
and width.

B. Input and Output Power

The unit converts AC input power to DC power for the
main cutting arc. The negative output is connected to
the torch electrode through the negative torch lead, and
the positive output connects to the workpiece through
the work cable.

C. Pilot Arc

When the torch is activated there is a 2 second (service
adjustable) gas pre-flow, followed by an uninterrupted
pulsed DC pilot arc established between the electrode and
tip. The pilot arc is initiated by a momentary high fre-
quency pulse from the Power Supply or the Optional
Remote Arc Starter. The pilot creates a path for the main
arc to transfer to the work. When the main arc is estab-
lished, the pilot arc shuts off. The pilot automatically re-
starts when the main arc stops, as long as the torch re-
mains activated.

D. Main Cutting Arc

The power supply converts the AC input power to DC
power for the main cutting arc. The negative output is
connected to the torch electrode through the negative
torch lead. The positive output is connected to the work-
piece via the work cable and ring lug connection.

E. RF Shielding

All machine torch systems are shielded to minimize radio
frequency (RF) interference which results from the high
frequency arc initiation. These shielded systems are de-
signed with features such as a wire for establishing an
earth ground and shielded torch and control leads. The
CNC control signals are filtered on an internal PC Board.

F. Interlocks

The system has several built-in interlocks to provide safe
and efficient operation. When an interlock shuts down
the system, the fault condition must be remedied and the
system recycled using the applicable control device.