5. when reinserting the swirl sleeve insert with the raised

directional arrows pointing into the ultraKlear

®

housing.

winter StOrage
the ultraKlear

®

filter should be shutdown, drained and

stored indoors or in a garage if your pond is subject to
below freezing weather. when disconnecting the tubing
from the filter, the threaded fittings should be removed
without the need for any tools (be careful not to lose the
flat rubber washers).

trOUbleShOOting

redUCed water FlOw
• the ultraKlear

®

will reduce the water flow on the pump.

it is recommended to use as large of a diameter of tubing
as possible (up to 1 ½ inch diameter) in order to achieve
maximum water flows.

• the ultraKlear

®

internal swirl sleeve could be clogged and

require cleaning.

• pump or plumbing may be clogged. it may be necessary

to clean the pump cage screens and impeller.

UV light iS nOt On
• a safety cut-off switch will activate if the ballast is not

properly connected to the uV housing. check that the
ballast is properly connected to the uV housing.

• power to the ultraKlear

®

has been lost. check to be sure

it’s plugged in and the ground fault breaker at the outlet is
not activated.

• uV internal bulb connection may be loose. open up uV

and inspect to make sure the bulb is securely plugged into
the ballast outlet.

• uV bulb could be beyond its life expectancy.

replace uV light.

95085 UltraKlear UV Clarifier Instructions FINAL 12-13.indd 10

12/12/13 4:39 PM

Advertising