INSTALLATION/OPERATION

3

Location


This appliance must be installed with the casters provided by the manufacturer, it cannot be curb mounted.
Curb mounting will seriously inhibit the appliance’s ability to effect proper combustion.

This appliance is for outdoor use only. To be used in well ventilated areas, and shall not be used in a building,
garage, or any other enclosed space. Do not locate this appliance under overhead unprotect combustible
surfaces.

Do not operate this appliance in adverse weather conditions. Operating or storing this appliance in adverse
weather conditions such as rain, sleet, snow, or high winds could cause property damage, injury or death.

Do not obstruct the flow of combustion and ventilation air.

Do not install near open windows and/or doors.

Minimum ambient temperature for safe use is -13°F (-25°C)

WARNING

This appliance must be installed with the casters provided by the manufacturer.

WARNING

This appliance must be installed on a firm and level surface, free of debris. Ensure the

appliance is stable (will not move or tip) prior to operation

WARNING

Lock swivel casters and place wheel chocks underneath large wheels prior to use. Do not

remove wheel chocks or unlock casters during operation.

Gas Connection

The gas line must be installed to meet the local building codes or National Fuel Gas Code ANS Z223.1 and
NFPA 54 (latest editions). In Canada, install the appliance in accordance with CSA B149.1 or .2 and local
codes. A properly sized and installed gas line will deliver a minimum supply pressure of 7.0 ± 2.0 inches w.c.
(17.4 ± 5 mbar) for natural gas and 12.0 ± 2.0 inches w.c. (29.9 ± 5 mbar) for propane gas to all appliances
connected to the supply line, operating simultaneously at full demand.

WARNING

NEVER supply the appliance with a gas other than the one that is indicated on the data

plate. Using the incorrect gas type will cause improper operation and could result in

serious injury or death. If you need to convert the appliance to another type of fuel,

contact the dealer you purchased it from.

NOTICE

NEVER use an adaptor to make a smaller gas supply line fit the appliance connection.

This may not allow proper gas flow for optimum burner operation, resulting in poor

performance and improper operation.

Fuel Supply Line Leak and Pressure Testing

The fuel supply system must be tested before the appliance is used. If the fuel line is going to be tested at a
pressure greater than ½ PISG (3.45 kPa), insure that that appliance is disconnected from the fuel line. If the fuel
line is to be tested at a pressure equal to or less than ½ PSIG (3.45 kPa), the appliance can be connected
during the test, but the unit’s gas valve must be shut. Test all gas line connections for leaks with a solution of
soap and water when pressure is applied. Do not test with an open flame.

Natural Gas Connections