Item

Check

• When installing the unit on a balcony, etc., secure an

evacuation route of 600mm (24") or more in width.

• Provide clearance of 600mm (24") or more in front of the

unit to facilitate inspection and repair. Do install the unit
such as the wall of the second floor where the unit is out
of reach.

• When installing the unit in a common side corridor, provide

a clearance of 1175mm (47") or more in front of the unit.

• Set the bottom edge of the exhaust port about 2100mm

(84") from the corridor floor.

Handrail

common side
corridor

balcony, etc.

Handrail

about
2100mm (84")

• Maintain the following clearance from both combustible

and non-combustible materials.

* ( ) indicates the distance when installing a heat insulat-

ing board (incombustible material other than metal, with
thickness of 2.5mm (0.1") or more) or "section of build-
ing effectively finished with incombustible material."
Note, however, that combustion failure may occur to the
unit as exhaust gas reflects from the wall. Provide clear-
ance of 600mm (24") or more in the front of the unit to
facilitate inspection and repair.

600mm (24")

(300mm (12"))

or more

10mm (0.4")
or more

combustible

900mm
(36") or more

150mm
(6") or more

150mm
(6") or more

Surrounding the area of installation

600mm (24")

or more

1175mm (47")
or more

Required Clearances From Heater

combustible

combustible

combustible

combustible

[ For N-0931M -OD]