Dimensions, Multi-system, N-0931m-dv – John Wood Noritz N-0931M_N-0931M-OD_N-0931M-DV Manuel d'utilisation

Page 62: A. installation without a recirculation system

Advertising
background image

62

15.

Dimensions

N-0931M-DV

16.

Multi-System

A. Installation without a recirculation system

• Insulate or apply heating materials to both the cold water supply piping and the hot water piping to

prevent freezing during cold weather and to prevent heat loss through the piping.

G

(1 1/4"-2")

(1 1/4"-2")

Unit No.6

Unit No.2

Unit
No.1

System Controller

System Select Connector

Hot Water Pipe

* Do not connect to
the connector.

* Disconnect this
connector
on units 2-6 also

Gas pipe

Cold Water Supply Pipe

Remote Controller

Disconnect this Connector

Disconnect for system controller

Install one system controller
(SC-201-6M) for every six units.

(120VAC)

WIRING THOROUGHWAY

WIRING THOROUGHWAYS

(VIEW FROM TOP)

HOT WATER OUTLET (3/4")

COLD WATER INLET (3/4")

GAS INLET (3/4")

73mm [2.9"]

155mm [6.1"]

100mm [3.9"]

195mm [7.7"]

366mm [14.4"]

279mm [11"]

136mm [5.4"]

175mm [6.9"]

159mm [6.3"]

135mm [5.3"]

70mm [2.8"]

65mm [2.6"]

170mm [6.7"]

140mm [5.5"]

100mm [3.9"]

70mm [2.8"]

36mm [1.4"]

170mm [6.7"]

140mm [5.5"]

100mm [3.9"]

70mm [2.8"]
36mm [1.4"]

665mm [26.2"]

28mm [1.1"]

77mm [3"]

240mm [9.4"]

95mm [3.7"]

586mm [23.1"]

10mm [0.4"]

10mm [0.4"]

40mm [1.6"]

(120VAC)

WIRING THROUGHWAY

WIRING THROUGHWAYS

COLD WATER INLET

WATER DRAIN VALVE
(WATER FILTER)

HOT WATER OUTLET

WATER DRAIN VALVE

GAS INLET

450mm [17.7"]

AIR INLET

FLUE COLLAR

LED

448mm [17.6"]

150mm [5.9"] 232mm [9.1"]

615mm [24.2"]

464mm [18.3"]

56mm [2.2"]

GAS INLET

55mm [2.2"]

COLD WATER INLET

44mm [1.7"]

HOT WATER OUTLET

N-0931M-DV

< mm [inch] >

FROM BOTTOM OF CASE

HEIGHT OF EACH FITTINGS

4- 13mm [ 0.5"]

6-6 x 10mm [0.24 x 0.4"] OBLONG HOLE

100mm [ 4"]

100mm [ 4"]

4- 13mm [ 0.5"]

6- 6 x 10mm [0.24 x 0.4"] OBLONG HOLE

Advertising