NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

SUPERIOR

®

B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • CARE AND OPERATION INSTRUCTIONS

OPERATION AND CARE OF YOUR APPLIANCE

WARNING

Young children should be carefully supervised when they are in the

same room as the appliance. Toddlers, young children and others

may be susceptible to accidental contact burns. A physical barrier is

recommended if there are at risk individuals in the house. To restrict

access to a fireplace or stove, install an adjustable safety gate to keep

toddlers, young children and other at risk individuals out of the room

and away from hot surfaces.

AVERTISSEMENT

Les jeunes enfants devraient être surveillés étroitement lorsqu’ils se trou-

vent dans la même pièce que l’appareil. Les tout petits, les jeunes enfants

ou les adultes peuvent subir des brûlures s’ils viennent en contact avec

la surface chaude. Il est recommandé d’installer une barrière physique

si des personnes à risques habitent la maison. Pour empêcher l’accès

à un foyer ou à un poêle, installez une barrière de sécurité; cette mesure

empêchera les tout petits, les jeunes enfants et toute autre personne à

risque d’avoir accès à la pièce et aux surfaces chaudes.

Figure 1

GAS CONTROLS / CONTROL

COMPARTMENT ACCESS

Fireplace gas controls are located in the lower

control compartment under the firebox (see

Figure 1). Remove the control compartment

door to access the controls.

To remove the control compartment door:
Gently pull upward and forward on the door

panel; then slide the panel, first to one side

and then to the other, until the door tabs clear

both holes (see Figure 2).

To reinstall the control compartment door:
Insert one of the door panel side tabs into its

corresponding hole in the control compartment

opening (see Figure 2); then insert the other

side tab. Lift upward on the door panel; then

gently push the top edge forward and down

into the grooves in the brackets until it locks

into place.

(Continued on next Page)

Figure 2

Control Compartment Door Tab

Gas Flex Line

(Gas Shut-Off Valve is behind

door latch; see DETAIL, below)

Gas Control

Valve

Piezo

(Millivolt

units only)

Spring

Door Latch

(one of two)

Lower Control

Compartment

(shaded area)

Optional

Unit-Mounted

ON/OFF Switch

~

{

Note: Millivolt system shown. Electronic system controls are similarly located.

DETAIL:

Gas Shut-Off Valve

in ON position (gas line OPEN)

To shut OFF gas: Turn valve handle

perpendicular (cross-wise) to gas line.

Advertising