Troubleshooting guide – millivolt control system – Superior SLBV 35/40 Manuel d'utilisation

Page 27

Advertising
background image

27

SUPERIOR

®

B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • CARE AND OPERATION INSTRUCTIONS

SYMPTOM

POSSIBLE CAUSES

CORRECTIVE ACTION

1. Spark igniter will not light pilot after

repeated triggering of igniter button.

WARNING: if the pilot will not light

after 1 minute of lighting attempts,

wait at least 5 minutes for gas to

clear before attempting again.

A. Defective igniter (no spark at electrode).

Check for spark at electrode and pilot; if no spark and

electrode wire is properly connected, replace igniter.

B. Defective or misaligned electrode at pilot

(spark at electrode).

Using a match, light pilot. If pilot lights, turn off pilot

and trigger the igniter button again. If pilot lights, an

improper gas mixture caused the bad lighting and a

longer purge period is recommended. If pilot will not

light, check gap at electrode and pilot; it should be

1/8" to have a strong spark.

C. Gas supply pressure errant.

Check inlet gas pressure. It should be within the limits

as marked on the rating plate.

D. Pilot orifice plugged.

Clean or replace pilot orifice.

2. Pilot will not stay lit after carefully

following the lighting instructions.

A. Defective pilot generator

(thermocouple).

Check pilot flame, it must impinge on thermocouple

(see Figure 14 on Page 16). Clean and/or adjust pilot

for maximum flame impingement on thermocouple.

Ensure that the connection between the valve and

thermocouple are tight and secure.

3. Pilot burning; no gas to burner;

valve knob set to “ON”; and

burner OFF/ON switch (unit-mounted

switch, wall switch, or remote

control) is set to “ON.”

A. Wall switch or wires defective.

Check wall switch and wires for proper connections.

Jumper wire across terminals at wall switch, if burner

comes on, replace defective wall switch. If okay, jumper

wires across wall switch wires at valve, if burner comes

on, wires are faulty or connections are bad.

B. Thermopile may not be generating

sufficient millivolts.

Check thermopile with millivolt meter. Take reading at

thermopile terminals of gas valve. Should read 325

millivolts minimum with optional wall switch in the

“OFF” position. Replace faulty thermopile if reading

is below specified minimum.

C. Plugged burner orifice.

Check burner orifice for blockage; remove, if found.

D. OFF/ON Switch and *Remote Switch are

in the ON position, resulting in excessive

resistance.

When turning on the burner using a *remote switch,

ensure that the standard OFF/ON switch is in the “OFF”

position. If both switches are in the “ON” position,

it may result in excessive resistance (and millivolt

drainage) and the burner may not come on.

4. Frequent pilot/burner outage

problem.

A. Pilot flame may be too low or blowing (high),

causing the pilot/valve safety to drop out.

Clean and/or adjust pilot flame for maximum flame

impingement on thermocouple (see Figure 14 on

Page 16).

TROUBLESHOOTING GUIDE – MILLIVOLT CONTROL SYSTEM

Note: Before troubleshooting the gas control system, make sure the external gas shut off valve (located at gas supply inlet)

and wall switch (if applicable) are in the “ON” position.

Important: Valve system troubleshooting should only be performed by a qualified service technician.