Spillage test – Superior SLBV 35/40 Manuel d'utilisation

Page 17

Advertising
background image

17

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

SUPERIOR

®

B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • CARE AND OPERATION INSTRUCTIONS

Figure 16

Figure 16-C

Limit Switch

Wire Terminals

(Red reset button

is between the

two terminals.)

Cabinet

Corner

Door

Frame

~

~

Figure 16-B

Figure 16-A

pull the switch/bracket assembly (with

low voltage wires attached) through the

side panel slot into the firebox.

8 - Replace the switch, if necessary.
9 - Reinstall the scoop and lintel.
10 - Reinstall the glass enclosure panel and

control compartment access panel.

The appliance should then relight and remain lit.

If this does not occur, contact your dealer.

SPILLAGE TEST

After appliance installation, perform this spillage

test to verify proper venting conditions:
1 - Place unit in its normally-operated condi-

tion, that is, with the glass enclosure panel

in place.

2 - Close all doors and windows in the room.

Turn on all exhaust fans in the house.

3 - Light the appliance.
4 - Wait 15 minutes.
5 - To check for venting action, start by hold-

ing a smoke producing device below the

glass enclosure panel. The smoke should

be drawn into the control compartment.

Continue the test by moving the smoke-

producing device along the entire length

of the lower edge of the glass enclosure

panel.

6 - If the smoke is NOT drawn into the con-

trol compartment, turn off the appliance

and call a qualified service technican.

Manually-Reset Safety Limit Switch

This appliance is equipped with a manually-

reset safety limit switch in the upper RIGHT

side of the firebox, behind the right side scoop.

Refer to Figure 16 for its location.
If, during appliance operation, the flame

goes out (independently of the burner ON/

OFF switch), the safety limit switch may have

tripped.
Some causes for a tripped safety limit switch

include the following:

• Incorrect flue configuration

• Blocked flue

• Negative pressure inside house

Before resetting the safety limit switch, have

a qualified service technician inspect the

fireplace and venting for these conditions and

repair as needed.

To RESET the safety limit switch, push the

reset button located between the wire terminals

on the back of the switch. Follow the steps be-

low to access the switch (also see Figure 16-C).

To REPLACE the safety limit switch, follow

the steps below.

IMPORTANT: This procedure should only be

performed by a qualified service technician.

1 - Turn OFF electrical power to appliance.
2
- Allow the appliance to cool.
3
- Remove the lower control compartment

access panel.

4 - Refer to Figure 6 on Page 11. Open both

latches under the firebox floor securing

the glass enclosure panel. Remove the

panel by tilting it outward at the bottom

and lifting it up. Set aside the panel, taking

care to protect it from damage.

5 - Remove the (3) screws securing the lintel,

and then remove the lintel. One of the lintel

cabinet top holes is shown in Figure 16.

6 - Remove the (3) screws securing the

scoop, and then remove the scoop. Refer

to Figure 16 for correct location for model

size.

7 - Reset the limit switch per Figure 16-B. If

unit does not reset, remove the (2) screws

securing the safety switch bracket, and

Safety Limit Switch / Reset Button Location

Inside View of Firebox (upper right side)

To access the Safety Limit Switch, reach in and up

behind the Bracket, and push the red reset button

located between the two Wire Terminals.

Upper Right Side of Firebox

(right side Scoop removed)

Lintel Screw Hole

in Cabinet Top

~

~

Bracket

(right side Scoop removed)

Right Side

Scoop

3 Scoop Screws

Lintel Screw Hole

in Cabinet Top

Right Side

of Firebox