Installation instructions, Warning, Countertop preparation – Jenn-Air Range Manuel d'utilisation

Page 9: Unpack range, Adjust leveling legs

Advertising
background image

9

Burner Input Requirements

Input ratings shown on the gas information plate are for
elevations up to 2,000 ft (609.6 m).

For elevations above 2,000 ft (609.6 m), ratings are reduced at a
rate of 4% for each 1,000 ft (304.8 m) above sea level (not
applicable for Canada).

Gas Supply Pressure Testing

Gas supply pressure for testing regulator must be at least
1" water column pressure above the manifold pressure shown on
the gas information plate.

Line pressure testing above ½ psi gauge (14" WCP)

The range and its individual shutoff valve must be disconnected
from the gas supply piping system during any pressure testing of
that system at test pressures in excess of ½ psi (3.5 kPa).

Line pressure testing at ½ psi gauge (14" WCP) or lower

The range must be isolated from the gas supply piping system by
closing its individual manual shutoff valve during any pressure
testing of the gas supply piping system at test pressures equal to
or less than ½ psi (3.5 kPa).

Countertop Preparation

(for Slide-in Ranges Only)

The cooktop sides of the slide-in range fit over the cutout edge of
your countertop.

If you have a square finish (flat) countertop and the opening width
is 30" (76.2 cm), no countertop preparation is required.

Formed front-edged countertops must have molded edge
shaved flat

³⁄₈" (1.0 cm) from each front corner of opening.

Tile countertops may need trim cut back

³⁄₈" (1.0 cm) from each

front corner and/or rounded edge flattened.

If countertop opening width is greater than 30" (76.2 cm), adjust
the

³⁄₈" (1.0 cm) dimension.

Countertop must be level. Place level on countertop, first side to
side, then front to back. If countertop is not level, range will not
be level. Range must be level for satisfactory baking conditions.

INSTALLATION INSTRUCTIONS

Unpack Range

1. Remove shipping materials, tape and film from the range.

Keep cardboard bottom under range.

2. Remove oven racks and parts package from inside oven.

3. To remove cardboard bottom, place range on its back, take

4 cardboard corners from the carton. Stack one cardboard
corner on top of another. Repeat with the other 2 corners.
Place them lengthwise on the floor behind the range to
support the range when it is laid on its back.

4. Using 2 or more people, firmly grasp the range and gently lay

it on its back on the cardboard corners.

5. Pull cardboard bottom firmly to remove.

6. Use an adjustable wrench to loosen the leveling legs.

7. Place cardboard or hardboard in front of range. Using 2 or

more people, stand range back up onto cardboard or
hardboard.

Adjust Leveling Legs

1. If range height adjustment is necessary, use a wrench or

pliers to loosen the 4 leveling legs.

This may be done with the range on its back or with the range
supported on 2 legs after the range has been placed back to
a standing position.

NOTE: To place range back up into a standing position, put a
sheet of cardboard or hardboard in front of range. Using 2 or
more people, stand range back up onto the cardboard or
hardboard.

2. Adjust the leveling legs to the correct height. Leveling legs

can be loosened to add up to a maximum of 1" (2.5 cm). A
minimum of

³⁄₁₆" (5 mm) is needed to engage the anti-tip

bracket.

NOTE: If height adjustment is made when range is standing,
tilt the range back to adjust the front legs, then tilt forward to
adjust the rear legs.

3. When the range is at the correct height, check that there is

adequate clearance under the range for the anti-tip bracket.
Before sliding range into its final location, check that the anti-
tip bracket will slide under the range and onto the rear
leveling leg prior to anti-tip bracket installation.

30"

(76.2 cm)

30 ¾"

(78.1 cm)

³⁄₈

"

(1.0 cm)

WARNING

Excessive Weight Hazard

Use two or more people to move and install range.

Failure to do so can result in back or other injury.