Rear Wall Venting

1. Mark the wall at the center of the cabinet opening.

2. Check for obstructions before marking the vent hole location.

Mark a horizontal line 8

³⁄₁₆" (20.8 cm) from the floor. Mark a

vertical line up to a maximum of 2¼" (7.9 cm) from the right
side of the cabinet centerline.

3. Draw and cut a 6¼" (15.8 cm) diameter hole.

4. Position blower motor in cabinet opening. Connect vent

system to blower motor outlet using a vent clamp.

5. Mount blower motor to the floor with 4 - #8 x ¾" hex head

screws provided.

6. Go to the “Make Gas Connection” section.

Floor Venting

1. Mark the floor at the center of the cabinet opening.

2. Position template on floor by matching the centerline of the

template to the centerline drawn on the floor and place
template 2¼" (5.7 cm) from the back wall.

3. Determine the correct position for the vent hole, depending

on obstructions (joists) in the floor.

The hole can be cut anywhere within the boundaries of either
hatched area.

Option 1: If using the back hatched area (bigger one), the
blower inlet must face the left side as shown on the template.
Option 2: If using the front hatched area (smaller one), the
blower inlet must face the back.

A. Maximum 2¼" (7.9 cm) from

the right of center

B. 8

³⁄₁₆

" (20.8 cm) from floor

A. 6¼" (15.8 cm)

Top View

A. 18¾" (47.6 cm) maximum from back

wall forward into cabinet opening

B. Inlet

C. Vent system
D. Vent clamp

E. Wall vent

A

B

A

A

B

C

D

E

Top View

Top View

Option 1

Option 2

A. Inlet from range
B. Exhaust outlet

A

A

B

B

Advertising