Warning, Connect range to downdraft system – Jenn-Air Range Manuel d'utilisation

Page 16

Advertising
background image

16

Connect Range to Downdraft System

1. Attach flexible vent (provided) to the blower motor inlet using

a vent clamp.

2. Check countertop height to allow range top to clear

countertop. Adjusting leveling legs if necessary.

3. Move range close to cabinet opening.

4. Plug into a grounded 3 prong outlet.

5. Plug range electrical connector into the downdraft blower

motor.

6. Remove cardboard or hardboard from under the range. Using

2 or more people, gently move range into its final location.

7. Check that the flexible connector and electrical cord are not

kinked. Use a flashlight to look underneath the bottom of the
range.

8. Verify that the anti-tip bracket is installed and engaged.

a.) Open access panel by grasping sides and pulling upward,

lifting out.

b.) Use a flashlight to look underneath the bottom of the

range.

c.) Visually check that the rear range foot is inserted into the

slot of the anti-tip bracket.

9. Level the range.

a.) Place rack in oven.

b.) Place level on rack and check levelness of the range, first

side to side; then front to back.

c.) If range is not level, pull range forward until rear leveling

leg is removed from the anti-tip bracket.

d.) Use a wrench or pliers to adjust leveling legs up or down

until range is level.

e.) Push range back into position.

f.) Check that rear leveling leg is engaged in anti-tip bracket.

NOTE: Range must be level for satisfactory baking
performance.

A. Inlet flexible vent
B. Vent clamp

A. Power supply cord
B. Range electrical connector to blower motor

1

2

1

A

B

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death,
fire, or electrical shock.

WARNING

A

B

Advertising