Electronic ignition system – Jenn-Air Range Manuel d'utilisation

Page 17

Advertising
background image

17

10. Depending on your installation, connect the flexible vent from

the blower motor inlet to the range using a vent clamp.

Wall Venting

Floor Venting

Side Venting
Connect flexible vent duct to range and connect vent system
to blower motor outlet.

11. Replace access panel by aligning catches with the studs on

the range. Press the access panel forward onto the studs and
drop downward to engage.

12. Insert downdraft vent filter and place vent grate over opening.

Replace grates and burner caps.

13. Reconnect power.

Electronic Ignition System

Initial lighting and gas flame adjustments

Cooktop and oven burners use pilotless igniters in place of
standing pilots. When the cooktop control knob is turned to the
“LITE” position, the system creates a spark to light the burner.
This sparking continues, as long as the control knob is turned to
“LITE.”

When the oven control is turned to the desired setting, a glow bar
igniter heats and ignites the gas.

Check Operation of Cooktop Burners

Standard Surface Burners

Push in and turn each control knob to the “LITE” position.

The flame should light within 4 seconds. The first time a burner is
lit, it may take longer than 4 seconds to light because of air in the
gas line.

If burners do not light properly:

Turn cooktop control knob to the “OFF” position.

Check that the range is plugged in and the circuit breaker has
not tripped or the household fuse has not blown.

Check that the gas shutoff valves are set to the “open”
position.

Top View

A. Range
B. Wall venting outlet

C. Vent clamp

Top View

A. Range
B. Floor venting outlet

C. Vent clamp

Top View

A. Flexible vent duct to range
B. Vent clamp

C. Range

D. Vent system

E. Side venting outlet

VENTING THROUGH WAL

A

B

C

C

A

B

BLOWER

B

E

C

A

D

A. Studs
B. Catches

A. Grate
B. Vent grate

C. Burner caps
D. Filter

A

B

A

A

B

D

C

C

Advertising