INTERMITTENT PILOT INSTRUCTIONS Continued

SWITCH

CENTRIFUGAL

CONTROL

SB6

25V

25V

GND

MAIN GAS VALVE

PILOT VALVE

MOTOR RELAY COIL

THERMOSTAT

TRANSFORMER

NEUT

HOT

MOTOR RELAY

MOTOR

EP SYSTEM

HONEYWELL

SWITCH

CENTRIFUGAL

TO ELECTRODE

BLUE

WHT

RED

GND

PV

MV/PV

MV

SB6

HONEYWELL

24V

RED

RED

YEL

YEL

MOTOR

BLK

BLK

BLK

MOTOR RELAY

WHT

YEL

BLK

BLK

TH/TR

TR

TH

VALVE

GAS

YEL

BLK

TRANSFORMER

L2

L1

T

T

TO THERMOSTAT

115V SUPPLY

COMMON

TO LINE

"A"

CORD

24V

TH-W

SPARK

12

3

4

5

6

7

9

8

Advertising