Intermittent pilot instructions continued – Garland AIR-DECK GAS BAKE AND PIZZA OVENS Manuel d'utilisation

Page 15

Advertising
background image

Part # 1382670 (12/07)

Page 15

THERMOSTAT (CONTROLLER)

CALLS FOR HEAT

1

SAFE-START CHECK

MUST NOT BE ANY FLAME OR

FLAME SIMULATING CONDITION

SPARK GENERATOR POWERED

FIRST VALVE (PILOT)

OPERATOR OPENS

2

POWER INTERRUPTION

SYSTEM SHUTS OFF, RESTARTS WHEN

POWER IS RESTORED.

PILOT FLAME FAILURE

SECOND MAIL OPERATOR CLOSES,

S86 STARTS TRAIL FOR IGNITION

3

IF FLAME OR FLAME SIMULATION

CONDITION PRESENT SYSTEM

FAILS TO START

4

PILOT BURNER LIGHTS
S86 SENSES FLAME CURRENT

PILOT BURNER OPERATION

OR

PILOT BURNER DOES NOT LIGHT
S86A OR B - TRIAL FOR IGNITION
CONTINUES, S86C OR D - GOES
INTO LOCKOUT AFTER TRIAL FOR
IGNITION TIMES OUT.

IF FLAME CURRENT SENSED

SPARK GENERATOR OFF.

SECOND VALVE OPERATOR

(MAIN) OPENS

5

6

MAIN BURNER OPERATION

S86 MONITORS PILOT FLAME

CURRENT

7

THERMOSTAT (CONTROLLER)

SATISFIED - VALVES CLOSED

PILOT AND MAIN BURNERS

ARE OFF.

START

STAGE 1

TRAIL FOR

IGNITION

STAGE 2

MAIN

BURNER

OPERATION

END

SEQUENCE OF OPERATION

INTERMITTENT PILOT INSTRUCTIONS Continued

Advertising