9

W415-0734 / D / 02.03.12

D.

Both the log support and the back wall must be removed in order to gain access to the vent connection
assembly. Both the back wall and log support are detached by removing the 12 perimeter screws of
the back wall and the 3 screws located at the back of the log support. Remove the vent connection
assembly. NOTE: The vent connection assembly collars are not specifi c until the stainless steel
fl ex liner has been attached to one side. This now designates the side as exhaust. The exhaust
collar must be positioned closest to the front
opening of the appliance. Secure and seal the fl ex
liners.

E.

To reinstall the vent connection assembly, reach
in through the appliance and manoeuvre the vent
connection assembly through the opening in the fi rebox
top. Take care not to damage the gasket. Secure the
assembly using the four studs and ¼-20 hex nuts.

F.

Reinstall the back wall, followed by the log support,
using the perimeter screws
removed in "D". The appliance
may now bepushed into its fi nal
position inside the wood burning
fi replace.Secure the appliance
to the fi replace using perforated
strapping attached to the two
securing holes on either side
of the appliance as shown. We
recommend that the trim be installed before the appliance is placed