18

W415-0734 / D / 02.03.12

7.4 FLAME

CHARACTERISTICS

7.3 VENTURI

ADJUSTMENT

This appliance has an air shutter that has been factory set open according
to the chart below:

Regardless of venturi orientation, closing the air shutter will cause a more
yellow flame, but can lead to carboning. Opening the air shutter will cause a
more blue flame, but can cause flame lifting from the burner ports. The
flame may not appear yellow immediately; allow 15 to 30 minutes for the
final flame colour to be established.

AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED
INSTALLER!

AIR
SHUTTER
OPENING

VENTURI
BURNER

ORIFICE

49.1

It’s important to periodically perform a visual check of the pilot and
burner fl ames. Compare them to the illustrations provided. If any fl ames
appear abnormal call a service person.

54.2

3/8” - 1/2”

FLAME MUST

ENVELOP UPPER

3/8" TO 1/2" OF

THERMOCOUPLE &

THERMOPILE

3"/ 3" LINER SYSTEM

FRONT REAR

NG

1/16"

3/16"

LP

3/16"

7/16"

AIR SHUTTER SETTING

2"/ 3" LINER SYSTEM

FRONT REAR

NG

1/8"

1/4"

LP

1/4"

5/8"

AIR SHUTTER SETTING

This appliance is approved for use with a 2" liner for air intake and a 3" liner for exhaust. For best performance,
however, it is recommended to use two 3" liners.
Air shutter settings will differ depending on the liner system used. Use the charts below to determine the
correct air shutter setting: