3.2 CHIMNEY

CONNECTION

A.

OUTSIDE: Slip the one end of a liner a minimum of 2" over the
collar of the air terminal. Secure using 3 screws. Then seal the
joint and screw heads with high temperature sealant. Repeat
with the other liner to the exhaust collar of the terminal.

NOTE: Connect the supplied 3' of stainless steel fl ex liner
to the exhaust liner (already attached to the terminal)
using the coupler (also supplied). Secure and seal before
dropping down the chimney.

B.

Gently stretch the liners to the required lengths and appliance
into the chimney. Place the terminal onto the top of the chimney
cap and fi t the fl ashing plate to suit. Make weather tight by sealing with
caulking (not supplied) and fasten to the chimney with screws and plugs
(not supplied).

C. NOTE: If there is not enough ceiling height between the fi replace

and the appliance to allow the fl ex liner connection on the top of
the appliance to be made, see "D".
If there is enough ceiling height,
connect the 3" stainless steel fl ex liner to the exhaust collar closest to the
top front on the appliance. Connect the intake fl ex liner to
the remaining rear collar. Secure and seal.

1-2" & 1-3" DOUBLE PLY ALUMINUM LINER-INLET AND EXHAUST &
2-3" TO 2" REDUCER:
GDI-2320KT

VENT KIT 20FT

GDI-2325KT

VENT KIT 25FT

GDI-2335KT

VENT KIT 35FT

2-3" DOUBLE PLY ALUMINUM LINER-INLET AND EXHAUST:
GDI-320KT

VENT KIT 20FT

GDI-325KT

VENT KIT 25 FT

GDI-335KT

VENT KIT 35 FT

Chimney installation must conform to both national and local code requirements. The chimney must be lined
with one 2" or 3" diameter liner for intake and one 3" diameter liner for exhaust. The minimum and maximum
vent lengths are 10 and 35 feet respectively. Recommended Napoleon® kits come in 3 lengths:

While the liners must be continuous from the appliance to the chimney cap, to achieve the needed length, they
may be coupled, using an aluminium coupler, provided installation is sealed & secured.

We recommend that exhaust vents that pass through unheated spaces, such as a garage or attic, be
wrapped in a protective sleeve to minimize condensation and reverse fl ow symptoms.
This appliance is approved for use with a 2" liner for air intake and a 3" liner for exhaust. For best
performance, however, it is recommended to use two 3" liners.
If a 2" liner is used for the intake, it is necessary to adjust the primary air shutter. See "Air Shutter
Settings".

ALUMINUM

FLEX LINER

COUPLER

STAINLESS

STEEL

FLEX LINER

2" OVERLAP

SEALANT

HI-TEMP

VENT
CONNECTION
ASSEMBLY

FLASHING

PLATE

2"

OVERLAP

SEALANT

HI-TEMP

EXHAUST

INTAKE