2.4 RATING PLATE / LIGHTING INSTRUCTION LOCATION

Both the rating plate and lighting instructions are attached to a cable and inserted in the slot on the lower left
side of the appliance. It is recommended to remove the door prior to instruction removal. Using your fi ngers or
a tool such as a screw driver or pencil, gently pull both cables toward you. With the cable at the bulb end of the
slot, wiggle the rating plate out being careful not to tear the instructions as they pass through the slot.

To replace, slide the instructions and the chain back through the slot and re-attach the door (if removed).

NOTE:

The rating plate must remain with the appliance at all times. It must not be removed.

!

WARNING

ALLOW THE APPLIANCE TO COOL BEFORE PERFORMING ANY MAINTENANCE OR CLEANING.

INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to
the model, venting and gas type of the appliance.

This illustration is for reference only. Refer to the rating plate on the appliance for accurate
information.

SAMPLE

W385-1864 / D

C E R T I F I E D

CLHD62N

CLHD62P

&(57,),('81'(5+202/2*8(6(/21/(61250(6$16,=E‡&6$E9(17('*$6),5(3/$&()2<(5­*$=9(17,/e

VENTED GAS FIREPLACE. APPROVED FOR BEDROOM, BATHROOM AND BED-SITTING ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE CURRENT
STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARD, TITLE 24 CFR, PART
3280. WHEN THIS US STANDARD IS NOT APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI/NFPA 501A. FOYER À
GAZ VENTILÉ. HOMOLOGUÉ POUR INSTALLATION DANS UNE CHAMBRE À COUCHER, UNE SALLE DE BAIN ET UN STUDIO. APPROPRIÉ POUR INSTALLATION DANS UNE MAISON MOBILE SI SON INSTALLATION
CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SÉRIE DE MAISONS MOBILES ÉQUIPÉES AU GAZ EN VIGEUR AU CANADA OU AUX ÉTATS-UNIS DE LA NORME DE SECURITE ET DE CONSTRUC-
TION DE MAISONS MANUFACTUREE, TITRE 24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D’ÉTATS-UNIS NE PEUT ETRE APPLIQUÉE, SE REFERER A LA NORME RELATIVE AU CRITÈRE DE
MESURES DE SÉCURITÉ CONTRE L’INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS MANUFACTURÉS, LES SITES ET LES COMMUNAUTÉS, ANSI/NFPA 501A. THIS APPLIANCE MUST BE INSTALLED IN
ACCORDANCE WITH LOCAL CODES, IF ANY; IF NONE, FOLLOW THE CURRENT ANSI Z223.1 OR CSA B149, INSTALLATION CODES. INSTALLER L’APPAREIL SELON LES CODES D’INSTALLATION ANSI Z223.1 OU
CSA-B149 EN VIGUER.

FOR USE WITH BARRIER W565-0137. FOLLOW THE INSTALLATION INSTRUCTIONS LOCATED IN THE INSTALLATION MANUAL.

POUR UNE UTILISER AVEC BARRIÈRE

W565-0137. SUIVEZ LES INSTRUCTIONS D'INSTALLATION SE TROUVENT DANS LE MANUEL D'INSTALLATION.

NOT FOR USE WITH

SOLID FUEL. FOR USE WITH

GLASS DOORS CERTIFIED
:,7+7+,681,721/<

CERTIFIED FOR / CERTIFIEE
POUR CANADA / USA

REFERENCE # 161746

WARNING:

'2127$''$1<0$7(5,$/

TO THE APPLIANCE, WHICH WILL COME IN
CONTACT WITH THE FLAMES, OTHER THAN
7+$76833/,('%<7+(0$18)$&785(5

WITH THE APPLIANCE
'(&25$7,9(352'8&7127)2586($6$

HEATING APPLIANCE.

MINIMUM CLEARANCE TO

COMBUSTIBLE MATERIALS:

TOP 0”

FLOOR 0”

RECESSED DEPTH

26”

SIDES 0”

BACK 0”
9(17723

9(176,'(6 %27720

9(57,&$/9(17

MANTEL 12”*
7236,'(6 %$&.3(567$1'2))63$&(56)25)5$0,1*

MATERIALS. FOR FINISHING MATERIALS SEE OWNER’S MANUAL
*MAXIMUM HORIZONTAL EXTENSION / L’EXTENSION HORIZONTALE
MAXIMALE: 2”. SEE INSTRUCTION MANUAL FOR GREATER
EXTENSIONS. SEE OWNER’S INSTRUCTION MANUAL FOR MINIMUM AND
MAXIMUM LENGTHS.

(/(&75,&$/5$7,1*9+=/(667+$1$03(5(6
WOLF STEEL LTD.

24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA

63e&,),&$7,216e/(&75,48(69

60HZ. MOINS DE 12 AMPÈRES.

LHD62N

LHD62P

MODEL PROPANE /

PROPANE MODÈLE

UN COMBUSTIBLE SOLIDE NE
3$6È75e87,/,6e$9(&&(7

$33$5(,/87,/,6(5$9(&/(6

3257(9,75e(6

+202/2*8e(66(8/(0(17

$9(&&(77(81,7e

$'9(57,66(0(17

N’AJOUTEZ PAS

$&(7$33$5(,/$8&810$7e5,$8'(9$17
(175(5(1&217$&7$9(&/(6)/$00(6
$875(48(&(/8,48,(67)2851,$9(&7

CET APPAREIL PAR LE FABRICANT.
352'8,7'e&25$7,)1(3$687,/,6(5

COMME APPAREIL DE CHAUFFAGE

'e*$*(0(1760,1,0$8;'(60$7e5,$8;

COMBUSTIBLES :
DESSUS 0”
PLANCHER 0”
352)21'(85'(/·(1&/$9()$&(µ
&Ñ7e6

µ

ARRIÈRE 0”
'(6686'8&21'8,7'·(9(17

&Ñ7e6(7'(66286'8&21'8,7
'·(9(17

µ

&21'8,7'·(9(179(57,&$/

TABLETTE 12”*

'(6686&Ñ7e6 $55,Ë5(6(/21/(6(63$&(856'(
'e*$*(0(173285/(60$7(5,$8;'·266$785(6(/21
/$0$18(/'(35235,e7$,5(3285/(60$7e5,$8;'(

FINITION. *L’EXTENSION HORIZONTALE MAXIMALE : 2”.
5e)e5(5$80$18$/'·,16758&7,213285'(6
(;7(16,2163/86*5$1'(65e)e5(5$80$18(/
'·,167$//$7,21'(35235,e7$,5(

MODEL NATURAL GAS /

GAZ NATURAL

0-4500FT (0-1370M)

$/7,78'(e/e9$7,21 0-4500FT

(0-1370M)

50,000

BTU/H

INPUT / ALIMENTATION 50,000

BTU/H



%78+ 5('8&(',1387$/,0(17$7,215e'8,7( ,000 BTU/H

3.5” WATER COLUMN/D’UNE COLONNE D’EAU

MANIFOLD PRESSURE /

10” WATER COLUMN/D’UNE COLONNE D’EAU

PRESSION

AU

COLLECTEUR

4.5“ WATER COLUMN/D’UNE COLONNE D’EAU

0,1,0806833/<35(6685(

11” WATER COLUMN/D’UNE COLONNE D’EAU

PRESSION D’ALIMENTATION MINIMALE

7.0“ WATER COLUMN/D’UNE COLONNE D’EAU

0$;,0806833/<35(6685(

13” WATER COLUMN/D’UNE COLONNE D’EAU

PRESSION D’ALIMENTATION MAXIMALE

55.3%

P.4

FE

55.3%

SERIAL NUMBER/ NO. DE SÉRIE:

LHD62

/·$33$5(,/'2,7e9$&8(56(6*$=(187,/,6$17
/·(16(0%/('·e9$&8$7,2135235($1$32/(215e)e5(5
$80$18(/'·,167$//$7,21'(35235,e7$,5(3285
/·(9$&8$7,2135(&,6(,/(67,03257$17'(%,(1
5e,167$//(5(75(6&(//(5/·(9(17$35e6$92,5$6685e
/(0$,17,(1'86<67e0('(35,6('·$,5

7+($33/,$1&(0687%(9(17('86,1*7+($335235,$7(

1$32/(219(17.,766((2:1(56,167$//$7,210$18$/

)259(17,1*63(&,),&63523(55(,167$//$7,21$1'

5(6($/,1*,61(&(66$5<$)7(56(59,&,1*7+(9(17$,5

,17$.(6<67(0

Advertising