7 terminaison horizontale – Napoleon Fireplaces Vector 62 - LHD62 Manuel d'utilisation

Page 74

Advertising
background image

FR

W415-1068 / A / 01.23.14

74

3.7 TERMINAISON

HORIZONTALE

(H

T

) < (V

T

)

Lorsque la confi guration de l’évacuation exige plus d’un coude de 90°, les formules suivants
s’appliquent:

Formule 1: H

T

< V

T

Formule 2: H

T

+ V

T

< 40 pieds (12m)

Exemple:
V

1

= 3 PI (1,5m)

V

2

= 8 PI (2,4m)

V

T

= V

1

+ V

2

= 3 PI (0,9m) + 8 PI (2,4m) = 11 PI (3,4m)

H

1

= 2.5 PI (0,7m)

H

2

= 2 PI (0,6m)

H

R

= H

1

+ H

2

= 2.5 (0,7m)+ 2 (0,6m) = 4.5 PI (1,4m)

H

O

= .03 (trois coude 90° - 90°) = .03 (270° - 90°) = 5.4 PI (1,6m)

H

T

= H

R

+ H

O

= 4.5 (1,4m) + 5.4 (1,6m) = 9.9 PI (3m)

H

T

+ V

T

= 9.9 (3m) + 11 (3,4m) = 20.9 PI (6,4m)

Formule 1:

H

T

< V

T

9.9 (3m) < 11 (3,4m)

Formule 2:

H

T

+ V

T

< 40 PI (12m)

20.9 (6,4m) < 40 (12m)

Puisque les deux formules sont respectées, cette confi guration d’évacuation est acceptable.

Consultex le graphique pour déterminer la course

verticale nécessaire V

T

par rapport à la course hori-

zontale requise H

T

.

The shaded area within the lines represents

acceptable values for H

T

and V

T

0

2.5

5

7.5

10

12.5

15

40

10

20

30

17.5

20

39

4

90°

90°

90°

V

1

V

2

H

1

H

2

COURSE

VERTICALE

REQUISE EN

PIEDS V

T

LONGUEUR DES COURSES HORIZONTALES PLUS

LES DÉVIATIONS EN PIEDS H

T

Confi guration d’évacuation simple (un coude de 90°
seulement)

Advertising