W415-1068 / B / 01.02.14

28

EN

* Within the appliance enclosure a minimum 7” (178mm) clearance between the top of the vent pipe and
combustible materials is required. All other clearances within the enclosure, including where the vent pipe exits
the enclosure are subject to 2” (51mm) to the sides and bottom and 3” (76mm) to the top for horizontal and 1”
(25mm) for vertical.

** See venting section.

IMPORTANT:

The LHD62 requires a minimum inside enclosure height of 96” (2.4m), measured from the

bottom of the appliance. For temperature requirements, this area must be left unobstructed. It is recommended
that the enclosure be ventilated at the top and bottom to circulate the hot air.

Before fi nishing in the appliance test the operation using the remote control, cycling it through all of its different

modes, see “OPERATION” section. Check pressure readings, see “PILOT BURNER ADJUSTMENT” section.

Once fi nished in, access to the control components can only be done through the inside of the appliance.

5.1 MINIMUM CLEARANCE TO COMBUSTIBLE ENCLOSURES

!

WARNING

THE FRONT OF THE APPLIANCE MUST BE FINISHED WITH ANY NON-COMBUSTIBLE MATERIALS
SUCH AS BRICK, MARBLE, GRANITE, ETC., AS LONG AS THESE MATERIALS NEVER OVERHANG

INTO THE APPLIANCE OPENING.

96”

(2438mm)

MINIMUM

ENCLOSURE

HEIGHT

TOP OF

ENCLOSURE

TOP OF

APPLIANCE

OPENING

7” (178mm)
MINIMUM

NOTE: JOINT COMPOUNDS AND TAPES
THAT ARE RESILIENT TO HEAT AND
CRACKING SHOULD BE USED WHEN
TAPING AND MUDDING SEAMS.

STEEL

STUD

FRAME

28”

(711mm)

MINIMUM

68”

(1727mm)

MINIMUM

COMBUSTIBLE

NON-COMBUSTIBLE

COMBUSTIBLE

9”

(228mm)

TO SIDEWALL

DRYWALL