Warning – Napoleon Fireplaces Vector 62 - LHD62 Manuel d'utilisation

Page 35

Advertising
background image

W415-1068 / B / 01.02.14

35

EN

6.3 GLASS MEDIA INSTALLATION

74.2C

Evenly spread the glass media onto the media tray, ensuring no glass media falls into the pilot opening. If this
happens, insert a clean bag into your vacuum cleaner and vacuum out the glass media. Replacement glass
can be purchased from your local authorized dealer / distributor.

NOTE: Do not use more media than what was supplied with the appliance.

CLEANING GLASS MEDIA
Glass media may have a fi ne oil residue that needs to be cleaned prior to installation. Clean the glass with mild
dish soap, drain, rinse thoroughly and dry before placing around the burner.

NOTE: A thin layer of glass media may cover the media tray and burner trough. Do not cover the
burner at the pilot opening.

BURNER
TROUGH

PILOT OPENING

MEDIA TRAY

COMBUSTION
AIR OPENING

NOTE: DO NOT PLACE MEDIA IN THE GAP AT THE REAR OF THE FIREBOX, BELOW
PORCELAIN PANELS. THIS IS THE COMBUSTION AIR OPENING, BLOCKING IT WILL RESULT IN
POOR PERFORMANCE.

CLEAN THE GLASS MEDIA PRIOR TO INSTALLATION. BEFORE APPLYING THE CLEANED GLASS, ENSURE

THAT IT IS DRY.

DO NOT CHANGE OR SUBSTITUTE THE GLASS MEDIA MATERIAL PROVIDED WITH THIS APPLIANCE. IF

REPLACING, USE ONLY THE REPLACEMENT GLASS MEDIA AVAILABLE FROM YOUR AUTHORIZED

DEALER / DISTRIBUTOR.

DO NOT PLACE ANY MEDIA (GLASS OR VERMICULITE) IN OR AROUND THE PILOT OPENING. THIS WILL

INTERFERE WITH THE PILOT OPERATION

!

WARNING

Advertising