Napoleon Fireplaces Vector 62 - LHD62 Manuel d'utilisation

Page 25

Advertising
background image

W415-1068 / B / 01.02.14

25

EN

*HORIZONTAL VENT SECTIONS:

A minimum clearance of 3” (76mm) to the top and 2” (51mm) to the

sides and bottom of the vent pipe on all horizontal runs to combustibles is required. Horizontal vent sections
within enclosures require a minimum clearance of 7” (178mm) at the top of the vent pipe, see “MINIMUM
CLEARANCE TO COMBUSTIBLE ENCLOSURES” section. Use fi restop assembly W010-2883 (supplied).

*VERTICAL VENT SECTIONS:

A minimum of 1” (25mm) all around the vent pipe on all vertical runs

to combustibles is required except for clearances in appliance enclosures. Vertical vent sections within
enclosures require a minimum clearance of 2” (51mm) around the vent pipe. Use fi restop spacer W500-0681
(not supplied).

27"

686mm

27"

686mm

81"

2057mm

81"

2057mm

81"

2057mm

9"

228mm

3"

76mm

124 7/8"

3171mm

83 5/16"

2117mm