Top of appliance, Warning, 4" 102mm – Napoleon Fireplaces Grandville 36 - BGD36 Manuel d'utilisation

Page 40: 8" 203mm, 2" 51mm, 6" 152mm

Advertising
background image

40

W415-0773 / F / 08.26.13

EN

TOP OF

APPLIANCE

WARNING: Non-combustible facing material may protrude from the top, and/or sides of this appliance,

as illustrated [up to a maximum of 6” (152.4mm)]. Greater than 6” (152.4mm) protrusions are considered a

mantel and must meet the combustible mantel requirements.

71.4B

4" (102mm)

2" (51mm)

6" (152mm)

FRONT OF

APPLIANCE

4" (102mm)

2" (51mm)

NON-COMBUSTIBLE

FACING MATERIAL

0" (0mm)

FINISH

MATERIAL

NON-COMBUSTIBLE

FACING MATERIAL

FINISH MATERIAL

2" (51mm)

4" (102mm)

6" (152mm)

4" (102mm)

2" (51mm)

0" (0mm)

6.6 NON-COMBUSTIBLE FACING MATERIAL

Combustible Mantel clearance can vary according to the Mantel depth. Use the graph
to help evaluate the clearance needed. These same requirements apply to any
combustibles protruding on either side of the appliance.

TOP OF APPLIANCE

6" 152mm

8"8" 203mm MANTEL

2" 51mm

4"

102mm

6"

152mm

8"

203mm

4" 102mm

2" 51mm

0

$

1

7

(

/

+

(

,

*

+

7



10” (254.0mm)

12” (304.8mm)

2

4

6

8 10 12

MANTEL DEPTH (INCHES)

8” (203.2mm)

4” (101.6mm)

6” (152.4mm)

2” (50.8mm)

!

WARNING

RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE

TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO

OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, MANTEL, FRONT, ETC.) ARE

CLEARLY MAINTAINED.

WHEN USING PAINT OR LACQUER TO FINISH THE MANTEL, THE PAINT OR LACQUER MUST BE

HEAT RESISTANT TO PREVENT DISCOLOURATION.

73.1

6.5 MINIMUM MANTEL CLEARANCES

Advertising