APPLIANCE

RECESS OR
ALCOVE
AREA

NOTE: Recesses or alcoves above the appliance can be made as deep as desired provided the minimum
clearances to combustibles are maintained.

Non-combustible material can be used, provided the minimum clearances to combustible materials are applied.

The minimum enclosure volume must be increased by no less than the volume of the recess. This adjustment
can be made by increasing any or all of the height, width and depth of the enclosure.

71.2

ENCLOSURE
AREA

6.4 ALCOVE

CLEARANCES

2" 51mm

1"

25mm

24" 610mm

MINIMUM

PLUS RISE*

2" 51mm

COMBUSTIBLE NON-COMBUSTIBLE

BRICK

0” (0MM) IF

NON-COMBUSTIBLE

FINISHING IS USED

SUCH AS BRICK

AND STONE.

39"

991mm

6" 152mm

MINIMUM

2" 51mm

1"

25mm

2" 51mm

COMBUSTIBLE NON-COMBUSTIBLE

BRICK

0” (0MM) IF

NON-COMBUSTIBLE

FINISHING IS USED

SUCH AS BRICK

AND STONE.

42 3/8"

1076mm

MINIMUM

PLUS RISE*

2" 51mm

MINIMUM

16"

406mm

1 1/2"

38mm

48 3/8"

1229mm

TOP EXIT ENCLOSURE
The appliance requires a minimum enclosure height
of 48 3/8" (1229mm). For temperature requirements,
the enclosure space around and above the appliance
must be left unobstructed.

REAR EXIT ENCLOSURE
The appliance requires a minimum enclosure height
of 39" (991mm). For temperature requirements, the
enclosure space around and above the appliance
must be left unobstructed.

* See "VENTING" section.