Napoleon Fireplaces Grandville 36 - BGD36 Manuel d'utilisation

Page 34

Advertising
background image

34

W415-0773 / F / 08.26.13

EN

Minimum clearance to combustible construction from appliance and vent surfaces:

Combustible

Framing:

-

0" to stand-offs

-

1" (25mm) to bottom and sides of the vent pipe*

-

2" (51mm) to top of the vent pipe*

Combustible Finishing:

-

0" to rear

-

0" to front face top and sides

-

14 1/4" (362mm) recessed depth

Rear Exit

-

42 1/4" (1073mm) to enclosure top from base of the appliance

-

54" (1372mm) to ceiling from base of the appliance

Top Exit

-

63" (1600mm) to enclosure top from base of the appliance

-

54" (1372mm) to ceiling from base of the appliance

* GD36 HORIZONTAL VENT SECTIONS:

A minimum clearance of 1" (25mm) at the bottom and sides and 2"

(51mm) at the top of the vent pipe on all horizontal runs to combustibles is required. Use fi restop spacer W010-
1777 (supplied).

* GD36 VERTICAL VENT SECTIONS:

A minimum of 1" (25mm) all around the vent pipe on all vertical runs

to combustibles is required except for clearances in appliance enclosures. See "MINIMUM ENCLOSURE
CLEARANCES" section. Use fi restop spacer W500-0096 (not supplied).

It is best to frame your appliance after it is positioned and the vent system is installed. Frame to local building
codes.
It is not necessary to install a hearth extension with this appliance system.
When roughing in the appliance, raise the appliance to accommodate for the thickness of the fi nished fl oor
materials, i.e. tile, carpeting, hard wood, which if not planned for will interfere with the opening of the lower
access door and the installation of many decorative fl ashing accessories.
Combustible materials may be installed fl ush with the front of the appliance but must not cover any of the
black face-areas of the appliance. Non-combustible material (brick, stone or ceramic tile) may protrude in
these areas.