Combustion protrusions such as mantels and shelves may occur at or after a minimum distance of 2" (51mm)
away from the side of the appliance. Thereafter, the depth of any protrusions must be equal to or less than the
distance from the side of the appliance up to a depth of 6" (152mm), after which no greater clearance than 6"
(152mm) is required. This can be considered a side wall with no length boundary.

6.2.1 MINIMUM FRAMING DIMENSIONS

36 1/2"

927mm

35 3/4"

908mm

3" 76mm

5 1/2" 140mm

14 1/2"

368mm

39" 991mm

(REAR EXIT)

48 3/8" 1229mm

(TOP EXIT)

3 1/2"

89mm

MAX

1 1/2"

38mm

MAX

14"

356mm

MINIMUM

GAS

INLET

LOCATION

FINISHING

MATERIAL

ENCLOSURE

TOP

TOP EXIT INSTALLATION

SHOWN

OUTSIDE

CHASE

INSIDE
CHASE

PROTRUSION

SIDE
WALL

14 1/2"

368mm

37 3/4" 959mm

37 3/4" 959mm

14 1/2"

368mm

2" 51mm

2" 51mm

4" 102mm

4" 102mm

6" 152mm

34 3/4"

882mm

49 1/8"

1247mm

35 1/2"

901mm

FOR TOP EXIT APPLICATIONS: DO NOT BUILD INTO THIS AREA. IT MUST BE LEFT CLEAR TO

PROVIDE ADEQUATE CLEARANCE FOR THE VENT. IN THIS 14" (356MM) WIDE AREA CENTRED

ALONG THE FRONT OF THE APPLIANCE, NO COMBUSTIBLES ARE ALLOWED.

!

WARNING

* BGD36 HORIZONTAL VENT SECTIONS:

A minimum of 1" (25mm) at the bottom and sides and 2" (51mm)

at the top of the vent pipe on all horizontal runs to combustibles is required. Use fi restop spacer W010-1774
(supplied).

* BGD36 VERTICAL VENT SECTIONS:

A minimum of 1" (25mm) all around the vent pipe on all vertical runs

to combustibles is required except for clearances in appliance enclosures. See "MINIMUM ENCLOSURE
CLEARANCES" section. Use fi restop spacer W500-0096 (not supplied).