Napoleon Fireplaces Grandville 36 - BGD36 Manuel d'utilisation

Page 20

Advertising
background image

20

W415-0773 / F / 08.26.13

EN

Simple venting configuration

(only two 90° elbows)

See graph to determine the required vertical rise V

T

for the

required horizontal run H

T

.

REQUIRED

VERTICAL RISE IN

INCHES

(MILLIMETERS)V

T

HORIZONTAL VENT RUN PLUS OFFSET IN FEET (METERS) H

T

The shaded area within the lines represents acceptable

values for H

T

and H

T

90°

V

1

V

2

H

1

H

2

90°

90°

90°

H

3

(H

T

) > (V

T

)

50 (1270)

100 (2540)

150(3810)

0

2.5

(0.8)

5

(1.5)

7.5

(2.3)

10

(3.1)

12.5
(3.8)

15

(4.6)

17.5
(5.3)

20

(6.1)

147 (3733.8

12

(304.8)

66

(1676.4)

1

(0.3)

3.5

(1.1)

19.25

(5.9)

16.3_2B

For vent configurations requiring more than two 90° elbows, the following formulas apply:

Formula 1: H

T

< 3.5V

T

Formula 2: H

T

+ V

T

< 24.75 feet (7.5m)

Example:
V

1

= 4 FT (1.2m)

V

2

= 1.5 FT (0.5m)

V

T

= V

1

+ V

2

= 4FT (1.2m) + 1.5FT (0.5m) = 5.5 FT (1.7m)

H

1

= 2 FT (0.6m)

H

2

= 1 FT (0.3m)

H

3

= 1 FT (0.3m)

H

4

= 1.5 FT (0.5m)

H

R

= H

1

+ H

2

+H

3

+H

4

= 2FT(0.6m) + 1FT(0.3m) + 1FT(0.3m) + 1.5FT(0.5m) = 5.5 FT(1.7m)

H

O

= .03 (four 90° elbows + one 45° elbow - 90°)

= .03 (90 + 90 + 90 + 90 + 45 - 90) = 9.45 FT (2.9m)
H

T

= H

R

+ H

O

= 5.5FT (1.7m) + 9.45FT (2.9m) = 14.95FT (4.6m)

H

T

+ V

T

= 14.95FT (4.6m) + 5.5FT (1.7m) = 20.45FT (6.2m)

Formula 1:

H

T

< 3.5V

T

3.5V

T

= 3.5FT (1.1m) x 5.5FT (1.7m) = 19.25FT (5.9m)

14.95 FT (4.6m) < 19.25 FT (5.9m)

Formula 2:

H

T

+ V

T

< 24.75 FT (7.5m)

20.45 FT (6.2m) < 24.75 FT (7.5m)

Since both formulas are met, this vent configuration is acceptable.