CHECKING THE INSTALLATION SITE

Clearances and dimensions

To install the range, refer to the following figure.

CAUTION

CAUTION

This range has been designed to comply with the maximum allowable wood

cabinet temperatures of 194 °F. Make sure the wall covering, countertops and cabinets around the

range can withstand the heat (up to 194 °F) generated by the range. If not, discoloration, delamination

or melting may occur.

A

B

A

36”~36-4/5”

31”

4-1/2”

23-1/5”

6-3/10”

24-7/10”

48”

28-3/5”

26-3/10”

29-4/5”

26-3/10”

Hatched Faces should be

flat and leveled.

35-7/8”

23-3/16”

1/2” min.

25”

6”

3”

24”

3”

1” min.

A : Cabinet opening
29-15/16”~30-1/16”

(76.04 - 76.28 cm)
B : Acceptable electrical

outlet area

* If your cabinet have height over 36-4/5”, this range cannot be installed without supporting unit

like hard block.

Minimum dimensions

IMPORTANT

To eliminate the risk of burns or fire caused by reaching over heated

surface units, avoid having cabinet storage space located above the surface units. If you have cabinet

storage space over the heating elements, you can reduce the risk by installing a range hood that

projects horizontally a minimum of 5 inches beyond the bottom of the cabinets.

* 30”

30”

** 15”

* 30” minimum clearance between the top of

the cooking surface and the bottom of an

unprotected wood or metal cabinet; or 24”

minimum when the bottom of the wood or

metal cabinet is protected by not less than

1

/

4

” of flame retardant millboard covered

with not less than no.28 MSG sheet steel,

0.015” stainless steel, 0.024” aluminum, or

0.020” copper.

** 15” minimum between the countertop and

the adjacent cabinet bottom.