Troubleshooting & repair, Typical scr gate voltage waveform – Lincoln Electric IDEALARC SP-250 Manuel d'utilisation

Page 83

Advertising
background image

F-36

TROUBLESHOOTING & REPAIR

F-36

IDEALARC SP-250

This is a typical SCR gate pulse voltage
waveform. The machine was in an open cir-
cuit condition (no load) and operating prop-
erly. Note that each vertical division repre-
sents 2 volts and each horizontal division
represents 5 milliseconds in time.

Note: Scope probes connected at Plug J3
on the control board. The (+) probe to lead
G2, and the (-) probe to lead 204.

Volts/Div . . . . . . . . . . . . . . . . . .2 V/Div.

Horizontal Sweep . . . . . . . . . .5 ms/Div.

Coupling . . . . . . . . . . . . . . . . . . . . .DC.

Trigger . . . . . . . . . . . . . . . . . . .Internal.

SCOPE SETTINGS

TYPICAL SCR GATE VOLTAGE WAVEFORM