F-5

TROUBLESHOOTING & REPAIR

F-5

IDEALARC SP-250

TROUBLESHOOTING GUIDE - Observe all Safety Guidelines detailed throughout this manual

OUTPUT PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENTS(S)

RECOMMENDED

COURSE OF ACTION

The output voltage and wire feed is
present continuously or pulsing
when gun trigger is NOT activated.

Output settings (voltage and/or wire
feed speed) are being changed even
though gun thumb switch or keypad
keys are not being activated.

No wire feed or open circuit voltage
when gun trigger is pulled. The dis-
play lights up but the audio alarm
and the display do not function prop-
erly.

1.

Check the machine's internal
trigger leads for grounds or
shorts. See Wiring Diagram.

2.

The control board may be faulty.
Replace.

1.

Check leads #326 and #327 for
grounds or shorts. See Wiring
Diagram.

2.

The Keypad may be faulty.
Perform the Keypad Test.

3.

The control board may be faulty.
Replace.

1.

Perform the Keypad Test.

2.

Perform the Main Transformer
Test.

3.

The control board may be faulty.-
Replace.

4.

The LCD display may be faulty. -
Replace.

1.

Remove the gun. If the problem
is resolved the gun trigger circuit
is faulty. Repair or replace.

2.

If the problem is not resolved
then contact your Local Lincoln
Electric Authorized Field Service
Facility.

1.

Remove the gun. If the problem
is resolved the gun thumb switch
circuit may be faulty. Repair or
replace.

2.

If the problem persists after gun
removal then the keypad may be
faulty. Check for burned or dam-
aged areas on the keypad.

1.

Check the input voltage at the
machine. Input voltage must
match the rating plate and the
reconnect panel - High or Low
Line message may be displayed.

2.

Remove the gun. If the problem
is resolved the gun is faulty.-
Replace.